| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 0.758 kW | |||
|---|---|---|---|
| 03/20/2026 15:51 (2123 days) | Production | Consumption | NET Usage |
| Now | 1.106 kW | 0.348 kW | -0.758 kW |
| Today | 18.698 kWh (1.178 kW) | 7.301 kWh (0.460 kW) | -11.397 kWh (-0.718 kW) |
| - This Week | 112.501 kWh (19.873 kWh/day) | 112.572 kWh (19.885 kWh/day) | 0.071 kWh (0.013 kWh/day) |
| - This Month | 347.222 kWh (17.660 kWh/day) | 316.599 kWh (16.103 kWh/day) | -30.623 kWh (-1.558 kWh/day) |
| - This Year | 0.981 MWh (12.473 kWh/day) | 1.416 MWh (18.007 kWh/day) | 0.435 MWh (5.534 kWh/day) |
| Yesterday | 13.403 kWh (0.558 kW) | 14.863 kWh (0.619 kW) | 1.460 kWh (0.061 kW) |
| Last 7 Days | 150.926 kWh (21.561 kWh/day) | 132.854 kWh (18.979 kWh/day) | -18.072 kWh (-2.582 kWh/day) |
| Last 30 Days (02/18/2026) | 450.597 kWh (15.020 kWh/day) | 500.380 kWh (16.679 kWh/day) | 49.783 kWh (1.659 kWh/day) |
| Last One Year | 6.085 MWh (16.670 kWh/day) | 7.888 MWh (21.610 kWh/day) | 1.803 MWh (4.939 kWh/day) |
| Lifetime Since PTO | 36.547 MWh (17.209 kW/day) | 40.927 MWh (19.272 kW/day) | 4.380 MWh (2.063 kW/day) |
| Lifetime Since Install | 36.581 MWh | 41.507 MWh | 4.926 MWh |
| Voltage/Current | 251.7 V / 4.4 A | 251.7 V / 1.4 A | 251.7 V / -3.0 A |
|
|||
| Micro-inverters [pcu_num:5, pcu_level:1] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 12/07/2025 23:55 (16.0 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.230 kW (0.014 kW/panel) | Today Energy | 10.555 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.205 | 0.631 | 0.628 | 3.970 | 0.000 kW 0.615 kWh |
0.000 kW 3.692 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.198 | 0.600 | 0.603 | 3.802 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.204 | 0.627 | 0.635 | 3.994 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.208 | 0.629 | 0.637 | 4.020 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.205 | 0.594 | 0.608 | 3.826 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.202 | 0.611 | 0.617 | 3.874 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.234 | 0.497 | 0.762 | 4.119 | 0.000 kW 0.626 kWh |
0.000 kW 3.132 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.249 | 0.642 | 0.782 | 4.666 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.239 | 0.696 | 0.789 | 4.927 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.248 | 0.689 | 0.786 | 4.859 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.239 | 0.607 | 0.793 | 4.634 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.104 | 0.386 | 0.298 | 1.661 | 0.000 kW 0.412 kWh |
0.000 kW 1.647 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.111 | 0.412 | 0.324 | 1.930 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.109 | 0.427 | 0.343 | 2.023 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.116 | 0.422 | 0.341 | 1.997 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.115 kW 1.042 kWh |
0.230 kW 2.083 kWh |
| 17 - 122214****** | IQ7PD | [5] VCOP | 0.230 | 0.230 | 2.083 | 0.000 | 0.000 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 0.69 V | Voltage Charge | 52.86 V | Current/Power | 0.00 A / 0.000 kW |
| Int/Ext Temp | 28.9 °C / 25.6 °C | Flags | 00/00/00 | Energy Today | 0.000 kWh @ 2025-12-07 23:59 |
|
|||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.13 V | Current/Power | -6.30 A (-0.335 kW) |
| Remain Capacity/Energy | 483.9 Ah (24.8 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 81.6 % | State Of Health | 98.9 % |
| Run Time | 3d 4h 48m to empty | Report Date | 2025-12-07 23:57 |
|
|||
| Voltage | 53.13 V | Cell (MIN/MAX) | 3.315 V / 3.326 V (0.011 V) |
|---|---|---|---|
| Current/Power | -1.92 A (-101 W) | Runtime | 3d 12h 14m to empty |
| Remain Capacity/Energy | 161.3 Ah (8.3 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 81.6 % | State Of Health | 98.8 % |
| Temperature | 18.5 °C | Cycle | 228 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-12-07 23:57 |
| Voltage | 53.12 V | Cell (MIN/MAX) | 3.318 V / 3.321 V (0.003 V) |
|---|---|---|---|
| Current/Power | -1.08 A (-57 W) | Runtime | 3d 9h 40m to empty |
| Remain Capacity/Energy | 88.1 Ah (4.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 88.6 % | State Of Health | 99.5 % |
| Temperature | 20.9 °C | Cycle | 160 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-12-07 23:57 |
| Voltage | 53.16 V | Cell (MIN/MAX) | 3.321 V / 3.323 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.09 A (-57 W) | Runtime | 3d 8h 39m to empty |
| Remain Capacity/Energy | 87.9 Ah (4.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 88.4 % | State Of Health | 99.5 % |
| Temperature | 19.9 °C | Cycle | 165 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-12-07 23:57 |
| Voltage | 53.11 V | Cell (MIN/MAX) | 3.318 V / 3.320 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.09 A (-57 W) | Runtime | 3d 8h 42m to empty |
| Remain Capacity/Energy | 88.0 Ah (4.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 88.4 % | State Of Health | 99.5 % |
| Temperature | 19.9 °C | Cycle | 167 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-12-07 23:56 |
| Voltage | 53.11 V | Cell (MIN/MAX) | 3.318 V / 3.320 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.12 A (-59 W) | Runtime | 3d 5h 27m to empty |
| Remain Capacity/Energy | 87.1 Ah (4.5 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 87.9 % | State Of Health | 99.2 % |
| Temperature | 20.6 °C | Cycle | 166 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-12-07 23:55 |