Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.336 kW
05/20/2026 05:17 (2184 days) Production Consumption NET Usage
Now 0.000 kW 0.336 kW 0.336 kW
Today 0.000 kWh (0.000 kW) 6.846 kWh (1.287 kW) 6.846 kWh (1.287 kW)
  - This Week 91.111 kWh (28.285 kWh/day) 93.826 kWh (29.128 kWh/day) 2.715 kWh (0.843 kWh/day)
  - This Month 492.927 kWh (25.646 kWh/day) 293.548 kWh (15.273 kWh/day) -199.379 kWh (-10.373 kWh/day)
  - This Year 2.446 MWh (17.569 kWh/day) 2.353 MWh (16.903 kWh/day) -0.093 MWh (-0.666 kWh/day)
Yesterday 28.907 kWh (1.205 kW) 38.153 kWh (1.591 kW) 9.246 kWh (0.386 kW)
Last 7 Days 191.372 kWh (27.339 kWh/day) 137.790 kWh (19.684 kWh/day) -53.582 kWh (-7.655 kWh/day)
Last 30 Days (04/20/2026) 721.439 kWh (24.048 kWh/day) 435.572 kWh (14.519 kWh/day) -285.867 kWh (-9.529 kWh/day)
Last One Year 6.368 MWh (17.447 kWh/day) 7.769 MWh (21.285 kWh/day) 1.401 MWh (3.838 kWh/day)
Lifetime Since PTO 38.012 MWh (17.403 kW/day) 41.864 MWh (19.167 kW/day) 3.852 MWh (1.764 kW/day)
Lifetime Since Install 38.046 MWh 42.444 MWh 4.398 MWh
Voltage/Current 251.7 V / 0.0 A 251.5 V / 1.3 A 251.6 V / 1.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/22/2023 23:37 (14.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.932 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.295 2.121 1.858 9.726 0.000 kW
2.000 kWh
0.000 kW
12.001 kWh
02 - 202244****** IQ7+M [0] V--- 0.000 0.283 1.970 1.785 9.230
03 - 202224****** IQ7+M [0] ---- 0.000 0.291 2.009 1.839 9.524
04 - 202232****** IQ7+ [0] ---- 0.000 0.293 2.057 1.847 9.617
05 - 202244****** IQ7+M [0] ---- 0.000 0.283 1.808 1.758 8.837
06 - 202245****** IQ7+M [0] ---- 0.000 0.290 2.037 1.821 9.418
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 1.902 1.811 8.969 0.000 kW
1.900 kWh
0.000 kW
9.499 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.867 1.757 8.876
09 - 202217****** IQ7+ [0] V--- 0.000 0.288 1.886 1.796 8.937
10 - 202244****** IQ7+M [0] ---- 0.000 0.285 1.903 1.803 9.004
11 - 202224****** IQ7+M [0] ---- 0.000 0.292 1.942 1.826 9.101
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.260 2.068 1.528 8.732 0.000 kW
2.099 kWh
0.000 kW
8.395 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.264 2.072 1.519 8.932
14 - 202216****** IQ7+ [0] ---- 0.000 0.266 2.124 1.597 9.285
15 - 202245****** IQ7+M [0] ---- 0.000 0.266 2.132 1.600 9.325
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.019 kWh
0.000 kW
2.037 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.230 2.037 1.135 8.103
Panel Layout Each Group Production

Battery History
Voltage 53.14 V Current/Power -10.01 A (-0.532 kW)
Remain Capacity/Energy 490.8 Ah (25.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 82.8 % State Of Health 98.9 %
Run Time 2d 1h 2m to empty Report Date 2023-07-22 23:57
voltag, current for each battery pack voltage, current, and SOC