Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
---|
Exporting to grid by 0.860 kW | |||
---|---|---|---|
06/05/2025 15:25 (1835 days) | Production | Consumption | NET Usage |
Now | 2.728 kW | 1.868 kW | -0.860 kW |
Today | 21.186 kWh (1.373 kW) | 9.954 kWh (0.645 kW) | -11.232 kWh (-0.728 kW) |
- This Week | 133.403 kWh (28.733 kWh/day) | 71.991 kWh (15.506 kWh/day) | -61.412 kWh (-13.227 kWh/day) |
- This Month | 133.403 kWh (28.733 kWh/day) | 71.991 kWh (15.506 kWh/day) | -61.412 kWh (-13.227 kWh/day) |
- This Year | 2.535 MWh (16.284 kWh/day) | 2.426 MWh (15.586 kWh/day) | -0.109 MWh (-0.698 kWh/day) |
Yesterday | 30.917 kWh (1.288 kW) | 20.432 kWh (0.851 kW) | -10.485 kWh (-0.437 kW) |
Last 7 Days | 164.065 kWh (23.436 kWh/day) | 149.292 kWh (21.325 kWh/day) | -14.773 kWh (-2.110 kWh/day) |
Last 30 Days | 593.506 kWh (19.783 kWh/day) | 543.711 kWh (18.123 kWh/day) | -49.795 kWh (-1.660 kWh/day) |
Last One Year | 6.543 MWh (17.927 kWh/day) | 6.270 MWh (17.178 kWh/day) | -0.273 MWh (-0.749 kWh/day) |
Lifetime Since PTO | 31.985 MWh (17.425 kW/day) | 34.378 MWh (18.728 kW/day) | 2.392 MWh (1.303 kW/day) |
Lifetime Since Install | 32.019 MWh | 34.958 MWh | 2.939 MWh |
Voltage/Current | 247.8 V / 11.0 A | 247.7 V / 7.5 A | 247.8 V / -3.5 A |
![]() ![]() ![]() ![]() |
Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Recent Report Data/Time | 07/31/2022 22:34 (13.7 hours) | Number of Devices | 16 set | |||||||
Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 25.304 kWh | |||||||
Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.296 | 1.752 | 1.936 | 11.037 | 0.000 kW 1.670 kWh |
0.000 kW 10.021 kWh |
02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.619 | 1.801 | 10.350 | |||
03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.297 | 1.702 | 1.867 | 10.753 | |||
04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.296 | 1.724 | 1.844 | 10.672 | |||
05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.295 | 1.557 | 1.699 | 9.805 | |||
06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.293 | 1.668 | 1.816 | 10.437 | |||
front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.296 | 1.601 | 1.764 | 10.042 | 0.000 kW 1.604 kWh |
0.000 kW 8.021 kWh |
08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.625 | 1.708 | 9.813 | |||
09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.295 | 1.584 | 1.704 | 9.804 | |||
10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.603 | 1.766 | 10.075 | |||
11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.608 | 1.799 | 10.164 | |||
back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.287 | 1.829 | 1.971 | 10.979 | 0.000 kW 1.815 kWh |
0.000 kW 7.262 kWh |
13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.287 | 1.792 | 1.871 | 10.650 | |||
14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.289 | 1.839 | 1.961 | 10.992 | |||
15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.284 | 1.802 | 1.910 | 10.794 | |||
wind | 16 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
![]() ![]() |
Battery History | |||
---|---|---|---|
Voltage | 53.17 V | Current/Power | -4.65 A (-0.247 kW) |
Remain Capacity/Energy | 572.4 Ah (29.3 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
State Of Charge | 95.4 % | State Of Health | 100.0 % |
Run Time | 5d 3h 6m to empty | Report Date | 2022-07-31 23:53 |
![]() ![]() ![]() |
Voltage | 53.20 V | Cell (MIN/MAX) | 3.320 V / 3.329 V (0.009 V) |
---|---|---|---|
Current/Power | -1.26 A (-67 W) | Runtime | 6d 6h 50m to empty |
Remain Capacity/Energy | 190.8 Ah (9.8 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
State Of Charge | 95.4 % | State Of Health | 100.0 % |
Temperature | 26.0 °C | Cycle | 72 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-07-31 23:53 |