Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
---|
Importing from grid by 0.393 kW | |||
---|---|---|---|
05/19/2025 01:04 (1818 days) | Production | Consumption | NET Usage |
Now | 0.000 kW | 0.393 kW | 0.393 kW |
Today | 0.000 kWh (0.000 kW) | 0.640 kWh (0.586 kW) | 0.640 kWh (0.586 kW) |
- This Week | 21.083 kWh (20.149 kWh/day) | 69.730 kWh (66.639 kWh/day) | 48.647 kWh (46.491 kWh/day) |
- This Month | 337.718 kWh (18.715 kWh/day) | 318.880 kWh (17.671 kWh/day) | -18.838 kWh (-1.044 kWh/day) |
- This Year | 2.161 MWh (15.654 kWh/day) | 2.128 MWh (15.412 kWh/day) | -0.033 MWh (-0.242 kWh/day) |
Yesterday | 21.083 kWh (0.878 kW) | 69.090 kWh (2.876 kW) | 48.007 kWh (1.999 kW) |
Last 7 Days | 123.582 kWh (17.654 kWh/day) | 160.365 kWh (22.909 kWh/day) | 36.783 kWh (5.255 kWh/day) |
Last 30 Days | 635.672 kWh (21.189 kWh/day) | 525.047 kWh (17.502 kWh/day) | -110.625 kWh (-3.688 kWh/day) |
Last One Year | 6.694 MWh (18.339 kWh/day) | 6.330 MWh (17.342 kWh/day) | -0.364 MWh (-0.996 kWh/day) |
Lifetime Since PTO | 31.612 MWh (17.388 kW/day) | 34.080 MWh (18.745 kW/day) | 2.468 MWh (1.357 kW/day) |
Lifetime Since Install | 31.646 MWh | 34.660 MWh | 3.014 MWh |
Voltage/Current | 251.9 V / 0.0 A | 252.0 V / 1.6 A | 251.9 V / 1.6 A |
![]() ![]() ![]() ![]() |
Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Recent Report Data/Time | 06/25/2022 23:08 (14.7 hours) | Number of Devices | 16 set | |||||||
Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 33.212 kWh | |||||||
Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.292 | 2.375 | 1.817 | 10.423 | 0.000 kW 2.239 kWh |
0.000 kW 13.435 kWh |
02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.284 | 2.240 | 1.735 | 9.866 | |||
03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.288 | 2.260 | 1.773 | 10.060 | |||
04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.288 | 2.260 | 1.760 | 9.930 | |||
05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.286 | 2.047 | 1.577 | 9.237 | |||
06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.281 | 2.251 | 1.758 | 9.961 | |||
front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.280 | 2.109 | 1.624 | 9.256 | 0.000 kW 2.099 kWh |
0.000 kW 10.496 kWh |
08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.282 | 1.991 | 1.598 | 9.053 | |||
09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.280 | 2.077 | 1.577 | 9.082 | |||
10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.282 | 2.160 | 1.626 | 9.292 | |||
11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.281 | 2.159 | 1.648 | 9.377 | |||
back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.261 | 2.371 | 1.865 | 10.793 | 0.000 kW 2.320 kWh |
0.000 kW 9.281 kWh |
13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.259 | 2.251 | 1.826 | 10.549 | |||
14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.261 | 2.358 | 1.876 | 10.863 | |||
15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.255 | 2.302 | 1.850 | 10.710 | |||
wind | 16 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
![]() ![]() |
Battery History | |||
---|---|---|---|
Voltage | 52.74 V | Current/Power | -1.59 A (-83 W) |
Remain Capacity/Energy | 231.3 Ah (11.8 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
State Of Charge | 38.6 % | State Of Health | 100.0 % |
Run Time | 6d 1h 28m to empty | Report Date | 2022-06-25 23:51 |
![]() ![]() ![]() |
Voltage | 52.76 V | Cell (MIN/MAX) | 3.289 V / 3.303 V (0.014 V) |
---|---|---|---|
Current/Power | -0.50 A (-26 W) | Runtime | 6d 10h 12m to empty |
Remain Capacity/Energy | 77.1 Ah (3.9 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
State Of Charge | 38.6 % | State Of Health | 100.0 % |
Temperature | 24.0 °C | Cycle | 68 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-25 23:51 |
Voltage | 52.72 V | Cell (MIN/MAX) | 3.294 V / 3.295 V (0.001 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 68.7 Ah (3.5 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
State Of Charge | 68.7 % | State Of Health | 100.0 % |
Temperature | 23.5 °C | Cycle | 20 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-25 23:51 |
Voltage | 52.76 V | Cell (MIN/MAX) | 3.296 V / 3.298 V (0.002 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 65.0 Ah (3.3 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
State Of Charge | 65.0 % | State Of Health | 100.0 % |
Temperature | 24.7 °C | Cycle | 21 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-25 23:57 |
Voltage | 52.74 V | Cell (MIN/MAX) | 3.295 V / 3.296 V (0.001 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 66.9 Ah (3.4 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
State Of Charge | 66.9 % | State Of Health | 100.0 % |
Temperature | 24.9 °C | Cycle | 21 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-25 23:57 |
Voltage | 52.73 V | Cell (MIN/MAX) | 3.295 V / 3.296 V (0.001 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 65.8 Ah (3.4 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
State Of Charge | 66.0 % | State Of Health | 99.7 % |
Temperature | 23.5 °C | Cycle | 21 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-25 23:51 |