| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 2.540 kW | |||
|---|---|---|---|
| 07/04/2026 22:48 (2229 days) | Production | Consumption | NET Usage |
| Now | 0.225 kW | 2.765 kW | 2.540 kW |
| Today | 33.151 kWh (1.452 kW) | 42.274 kWh (1.851 kW) | 9.123 kWh (0.399 kW) |
| - This Week | 209.103 kWh (30.084 kWh/day) | 244.191 kWh (35.132 kWh/day) | 35.088 kWh (5.048 kWh/day) |
| - This Month | 127.502 kWh (32.269 kWh/day) | 170.051 kWh (43.037 kWh/day) | 42.549 kWh (10.768 kWh/day) |
| - This Year | 3.737 MWh (20.207 kWh/day) | 3.457 MWh (18.691 kWh/day) | -0.281 MWh (-1.517 kWh/day) |
| Yesterday | 33.078 kWh (1.378 kW) | 41.779 kWh (1.741 kW) | 8.701 kWh (0.363 kW) |
| Last 7 Days | 209.103 kWh (29.872 kWh/day) | 244.976 kWh (34.997 kWh/day) | 35.873 kWh (5.125 kWh/day) |
| Last 30 Days (06/04/2026) | 850.535 kWh (28.351 kWh/day) | 829.113 kWh (27.637 kWh/day) | -21.422 kWh (-0.714 kWh/day) |
| Last One Year | 6.723 MWh (18.420 kWh/day) | 7.747 MWh (21.226 kWh/day) | 1.024 MWh (2.805 kWh/day) |
| Lifetime Since PTO | 39.303 MWh (17.625 kW/day) | 42.968 MWh (19.268 kW/day) | 3.665 MWh (1.643 kW/day) |
| Lifetime Since Install | 39.337 MWh | 43.548 MWh | 4.211 MWh |
| Voltage/Current | 249.4 V / 0.9 A | 249.3 V / 11.1 A | 249.4 V / 10.2 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 08/02/2023 23:25 (14.0 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 32.024 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.296 | 2.097 | 2.108 | 13.925 | 0.000 kW 1.998 kWh |
0.000 kW 11.990 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 1.964 | 1.975 | 13.059 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 2.018 | 2.030 | 13.421 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 2.071 | 2.074 | 13.688 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 1.828 | 1.844 | 12.259 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 2.012 | 2.032 | 13.426 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 1.973 | 1.949 | 12.983 | 0.000 kW 1.959 kWh |
0.000 kW 9.796 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 1.915 | 1.874 | 12.637 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 1.929 | 1.897 | 12.780 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 1.973 | 1.948 | 12.988 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 2.006 | 1.991 | 13.210 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.261 | 1.956 | 1.967 | 12.670 | 0.000 kW 1.990 kWh |
0.000 kW 7.962 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.268 | 1.933 | 1.938 | 12.543 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.269 | 2.034 | 2.036 | 13.138 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.271 | 2.038 | 2.041 | 13.174 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.759 kWh |
0.000 kW 2.276 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.230 | 2.276 | 1.367 | 8.704 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.05 V | Current/Power | -4.20 A (-0.223 kW) |
| Remain Capacity/Energy | 450.4 Ah (23.1 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 75.9 % | State Of Health | 98.9 % |
| Run Time | 4d 11h 13m to empty | Report Date | 2023-08-02 23:58 |
|
|||
| Voltage | 52.84 V | Cell (MIN/MAX) | 3.288 V / 3.314 V (0.026 V) |
|---|---|---|---|
| Current/Power | -13.65 A (-721 W) | Runtime | 10h 59m to empty |
| Remain Capacity/Energy | 150.1 Ah (7.7 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 75.9 % | State Of Health | 98.8 % |
| Temperature | 25.0 °C | Cycle | 113 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-02 23:58 |
| Voltage | 53.02 V | Cell (MIN/MAX) | 3.313 V / 3.314 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.17 A (-9 W) | Runtime | 21d 14h 51m to empty |
| Remain Capacity/Energy | 90.8 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 91.3 % | State Of Health | 99.5 % |
| Temperature | 24.9 °C | Cycle | 58 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-02 23:59 |
| Voltage | 53.02 V | Cell (MIN/MAX) | 3.312 V / 3.314 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.56 A (-29 W) | Runtime | 6d 16h 35m to empty |
| Remain Capacity/Energy | 90.4 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 90.9 % | State Of Health | 99.5 % |
| Temperature | 25.7 °C | Cycle | 61 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-02 23:59 |
| Voltage | 53.01 V | Cell (MIN/MAX) | 3.312 V / 3.313 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.83 A (-43 W) | Runtime | 4d 12h 58m to empty |
| Remain Capacity/Energy | 90.0 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 90.5 % | State Of Health | 99.5 % |
| Temperature | 26.1 °C | Cycle | 63 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-02 23:59 |
| Voltage | 53.02 V | Cell (MIN/MAX) | 3.313 V / 3.314 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.55 A (-28 W) | Runtime | 6d 21h 51m to empty |
| Remain Capacity/Energy | 90.4 Ah (4.6 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 91.1 % | State Of Health | 99.2 % |
| Temperature | 24.8 °C | Cycle | 61 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-02 23:59 |