Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.614 kW
06/06/2025 09:26 (1836 days) Production Consumption NET Usage
Now 1.923 kW 0.309 kW -1.614 kW
Today 2.849 kWh (0.301 kW) 6.628 kWh (0.699 kW) 3.779 kWh (0.399 kW)
  - This Week 142.817 kWh (26.476 kWh/day) 94.681 kWh (17.552 kWh/day) -48.136 kWh (-8.924 kWh/day)
  - This Month 142.817 kWh (26.476 kWh/day) 94.681 kWh (17.552 kWh/day) -48.136 kWh (-8.924 kWh/day)
  - This Year 2.544 MWh (16.266 kWh/day) 2.449 MWh (15.657 kWh/day) -0.095 MWh (-0.610 kWh/day)
Yesterday 27.751 kWh (1.157 kW) 26.016 kWh (1.084 kW) -1.735 kWh (-0.072 kW)
Last 7 Days 179.460 kWh (25.640 kWh/day) 161.662 kWh (23.097 kWh/day) -17.798 kWh (-2.543 kWh/day)
Last 30 Days 615.800 kWh (20.527 kWh/day) 555.436 kWh (18.515 kWh/day) -60.364 kWh (-2.012 kWh/day)
Last One Year 6.543 MWh (17.927 kWh/day) 6.277 MWh (17.196 kWh/day) -0.267 MWh (-0.731 kWh/day)
Lifetime Since PTO 31.995 MWh (17.423 kW/day) 34.401 MWh (18.733 kW/day) 2.406 MWh (1.310 kW/day)
Lifetime Since Install 32.029 MWh 34.981 MWh 2.952 MWh
Voltage/Current 248.6 V / 7.7 A 248.5 V / 1.2 A 248.5 V / -6.5 A
Meter Accumulated Grid Votlage Power

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_panel_inc.php on line 411

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/02/2022 23:05 (14.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.346 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.291 1.794 2.129 14.022 0.000 kW
1.759 kWh
0.000 kW
10.556 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.736 2.007 13.164
03 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.779 2.049 13.406
04 - 202232****** IQ7+ [5] VCOP 0.000 0.291 1.772 2.044 13.307
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.729 1.870 12.164
06 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.746 2.016 13.328
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 1.698 1.929 12.470 0.000 kW
1.676 kWh
0.000 kW
8.378 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.610 1.904 12.091
09 - 202217****** IQ7+ [5] VCOP 0.000 0.290 1.631 1.909 12.245
10 - 202244****** IQ7+M [5] VCOP 0.000 0.290 1.704 1.938 12.606
11 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.735 1.942 12.665
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.288 1.624 2.184 14.168 0.000 kW
1.603 kWh
0.000 kW
6.411 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.287 1.552 2.112 13.616
14 - 202216****** IQ7+ [5] VCOP 0.000 0.288 1.631 2.175 14.141
15 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.604 2.133 13.872
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.26 A (-67 W)
Remain Capacity/Energy 525.6 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.6 % State Of Health 100.0 %
Run Time 17d 9h 8m to empty Report Date 2022-07-02 23:51
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.23 V Cell (MIN/MAX) 3.321 V / 3.331 V (0.010 V)
Current/Power -0.45 A (-24 W) Runtime 16d 4h 28m to empty
Remain Capacity/Energy 175.2 Ah (9.0 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 87.6 % State Of Health 100.0 %
Temperature 25.0 °C Cycle 69
MOSFET CFET = ON, DFET = ON Reported 2022-07-02 23:51
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.323 V 3.323 V 3.324 V 3.325 V 3.326 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.328 V 3.328 V 3.328 V 3.329 V 3.330 V 3.331 V 3.331 V 3.330 V
pack voltage and current cell voltages
pack temperature