| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.277 kW | |||
|---|---|---|---|
| 07/05/2026 00:11 (2230 days) | Production | Consumption | NET Usage |
| Now | 0.225 kW | 0.502 kW | 0.277 kW |
| Today | 0.047 kWh (0.222 kW) | 0.117 kWh (0.552 kW) | 0.070 kWh (0.330 kW) |
| - This Week | 0.047 kWh | 0.117 kWh | 0.070 kWh |
| - This Month | 127.811 kWh (31.885 kWh/day) | 171.580 kWh (42.804 kWh/day) | 43.769 kWh (10.919 kWh/day) |
| - This Year | 3.738 MWh (20.203 kWh/day) | 3.458 MWh (18.693 kWh/day) | -0.279 MWh (-1.510 kWh/day) |
| Yesterday | 33.413 kWh (1.392 kW) | 43.686 kWh (1.820 kW) | 10.273 kWh (0.428 kW) |
| Last 7 Days | 209.412 kWh (29.916 kWh/day) | 245.635 kWh (35.091 kWh/day) | 36.223 kWh (5.175 kWh/day) |
| Last 30 Days (06/05/2026) | 850.406 kWh (28.347 kWh/day) | 829.840 kWh (27.661 kWh/day) | -20.566 kWh (-0.686 kWh/day) |
| Last One Year | 6.724 MWh (18.421 kWh/day) | 7.747 MWh (21.226 kWh/day) | 1.024 MWh (2.805 kWh/day) |
| Lifetime Since PTO | 39.303 MWh (17.625 kW/day) | 42.969 MWh (19.269 kW/day) | 3.666 MWh (1.644 kW/day) |
| Lifetime Since Install | 39.337 MWh | 43.549 MWh | 4.212 MWh |
| Voltage/Current | 251.1 V / 0.9 A | 251.0 V / 2.0 A | 251.0 V / 1.1 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 07/26/2023 23:29 (14.1 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 31.146 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.291 | 2.069 | 1.169 | 11.683 | 0.000 kW 1.969 kWh |
0.000 kW 11.816 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.277 | 1.932 | 1.076 | 10.991 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.284 | 1.988 | 1.099 | 11.301 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.291 | 2.034 | 1.136 | 11.498 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.277 | 1.803 | 0.929 | 10.384 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.283 | 1.989 | 1.107 | 11.279 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.289 | 1.911 | 0.960 | 10.747 | 0.000 kW 1.904 kWh |
0.000 kW 9.518 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.290 | 1.868 | 0.956 | 10.572 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.289 | 1.886 | 0.954 | 10.657 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.286 | 1.910 | 0.976 | 10.758 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.290 | 1.943 | 0.984 | 10.928 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.241 | 1.905 | 1.286 | 10.792 | 0.000 kW 1.943 kWh |
0.000 kW 7.772 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.248 | 1.903 | 1.311 | 10.890 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.250 | 1.977 | 1.342 | 11.280 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.247 | 1.987 | 1.350 | 11.322 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.680 kWh |
0.000 kW 2.040 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.230 | 2.040 | 1.117 | 10.476 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.15 V | Current/Power | -10.87 A (-0.578 kW) |
| Remain Capacity/Energy | 490.3 Ah (25.1 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 82.7 % | State Of Health | 98.9 % |
| Run Time | 1d 21h 6m to empty | Report Date | 2023-07-26 23:58 |
|
|||
| Voltage | 53.18 V | Cell (MIN/MAX) | 3.317 V / 3.329 V (0.012 V) |
|---|---|---|---|
| Current/Power | -3.13 A (-166 W) | Runtime | 2d 4h 16m to empty |
| Remain Capacity/Energy | 163.4 Ah (8.4 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 82.7 % | State Of Health | 98.8 % |
| Temperature | 25.5 °C | Cycle | 112 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-26 23:58 |
| Voltage | 53.13 V | Cell (MIN/MAX) | 3.320 V / 3.321 V (0.001 V) |
|---|---|---|---|
| Current/Power | -2.17 A (-115 W) | Runtime | 1d 17h 41m to empty |
| Remain Capacity/Energy | 90.7 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 91.2 % | State Of Health | 99.5 % |
| Temperature | 25.2 °C | Cycle | 57 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-26 23:58 |
| Voltage | 53.17 V | Cell (MIN/MAX) | 3.322 V / 3.323 V (0.001 V) |
|---|---|---|---|
| Current/Power | -2.10 A (-111 W) | Runtime | 1d 18h 53m to empty |
| Remain Capacity/Energy | 90.3 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 90.8 % | State Of Health | 99.5 % |
| Temperature | 26.2 °C | Cycle | 60 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-26 23:57 |
| Voltage | 53.12 V | Cell (MIN/MAX) | 3.319 V / 3.320 V (0.001 V) |
|---|---|---|---|
| Current/Power | -2.22 A (-118 W) | Runtime | 1d 16h 26m to empty |
| Remain Capacity/Energy | 89.9 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 90.4 % | State Of Health | 99.5 % |
| Temperature | 26.6 °C | Cycle | 62 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-26 23:57 |
| Voltage | 53.13 V | Cell (MIN/MAX) | 3.320 V / 3.322 V (0.002 V) |
|---|---|---|---|
| Current/Power | -2.06 A (-109 W) | Runtime | 1d 19h 52m to empty |
| Remain Capacity/Energy | 90.3 Ah (4.6 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 91.0 % | State Of Health | 99.2 % |
| Temperature | 25.2 °C | Cycle | 60 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-26 23:56 |