Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
---|
Importing from grid by 6.608 kW | |||
---|---|---|---|
05/18/2025 22:45 (1817 days) | Production | Consumption | NET Usage |
Now | 0.000 kW | 6.608 kW | 6.608 kW |
Today | 21.083 kWh (0.925 kW) | 66.459 kWh (2.915 kW) | 45.376 kWh (1.990 kW) |
- This Week | 21.083 kWh (22.193 kWh/day) | 66.459 kWh (69.958 kWh/day) | 45.376 kWh (47.765 kWh/day) |
- This Month | 337.718 kWh (18.815 kWh/day) | 315.609 kWh (17.584 kWh/day) | -22.109 kWh (-1.232 kWh/day) |
- This Year | 2.161 MWh (15.665 kWh/day) | 2.124 MWh (15.399 kWh/day) | -0.037 MWh (-0.266 kWh/day) |
Yesterday | 26.376 kWh (1.099 kW) | 22.695 kWh (0.946 kW) | -3.681 kWh (-0.153 kW) |
Last 7 Days | 134.879 kWh (19.270 kWh/day) | 110.358 kWh (15.767 kWh/day) | -24.521 kWh (-3.503 kWh/day) |
Last 30 Days | 642.393 kWh (21.414 kWh/day) | 468.858 kWh (15.629 kWh/day) | -173.535 kWh (-5.785 kWh/day) |
Last One Year | 6.688 MWh (18.322 kWh/day) | 6.275 MWh (17.193 kWh/day) | -0.412 MWh (-1.129 kWh/day) |
Lifetime Since PTO | 31.612 MWh (17.389 kW/day) | 34.076 MWh (18.744 kW/day) | 2.464 MWh (1.356 kW/day) |
Lifetime Since Install | 31.646 MWh | 34.656 MWh | 3.010 MWh |
Voltage/Current | 248.6 V / 0.0 A | 248.6 V / 26.6 A | 248.6 V / 26.6 A |
![]() ![]() ![]() ![]() |
Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Recent Report Data/Time | 06/01/2022 21:43 (13.0 hours) | Number of Devices | 16 set | |||||||
Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 16.893 kWh | |||||||
Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.290 | 1.181 | 2.088 | 12.804 | 0.000 kW 1.157 kWh |
0.000 kW 6.941 kWh |
02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.287 | 1.123 | 1.965 | 12.088 | |||
03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.291 | 1.187 | 1.992 | 12.467 | |||
04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.292 | 1.162 | 1.995 | 12.309 | |||
05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.288 | 1.144 | 1.812 | 11.622 | |||
06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.282 | 1.145 | 1.988 | 12.244 | |||
front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.291 | 1.092 | 1.847 | 11.695 | 0.000 kW 1.087 kWh |
0.000 kW 5.433 kWh |
08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.291 | 1.101 | 1.801 | 11.336 | |||
09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.291 | 1.061 | 1.812 | 11.438 | |||
10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.292 | 1.077 | 1.865 | 11.740 | |||
11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.291 | 1.102 | 1.878 | 11.880 | |||
back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.263 | 1.115 | 2.073 | 12.616 | 0.000 kW 1.130 kWh |
0.000 kW 4.519 kWh |
13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.266 | 1.127 | 2.015 | 12.264 | |||
14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.268 | 1.144 | 2.068 | 12.710 | |||
15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.264 | 1.133 | 2.034 | 12.554 | |||
wind | 16 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
![]() ![]() |
Battery History | |||
---|---|---|---|
Voltage | 54.74 V | Current/Power | 0.00 A (0 W) |
Remain Capacity/Energy | 531.6 Ah (27.2 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
State Of Charge | 88.6 % | State Of Health | 100.0 % |
Run Time | Stand-by | Report Date | 2022-06-01 23:52 |
![]() ![]() ![]() |
Voltage | 54.70 V | Cell (MIN/MAX) | 3.414 V / 3.422 V (0.008 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 177.2 Ah (9.1 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
State Of Charge | 88.6 % | State Of Health | 100.0 % |
Temperature | 23.0 °C | Cycle | 66 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-01 23:52 |
Voltage | 54.76 V | Cell (MIN/MAX) | 3.420 V / 3.424 V (0.004 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
State Of Charge | 99.5 % | State Of Health | 100.0 % |
Temperature | 22.1 °C | Cycle | 18 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-01 23:52 |
Voltage | 54.76 V | Cell (MIN/MAX) | 3.405 V / 3.424 V (0.019 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
State Of Charge | 99.5 % | State Of Health | 100.0 % |
Temperature | 23.4 °C | Cycle | 18 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-01 23:50 |
Voltage | 54.75 V | Cell (MIN/MAX) | 3.403 V / 3.424 V (0.021 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
State Of Charge | 99.5 % | State Of Health | 100.0 % |
Temperature | 23.7 °C | Cycle | 18 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-01 23:52 |
Voltage | 54.73 V | Cell (MIN/MAX) | 3.411 V / 3.422 V (0.011 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 99.2 Ah (5.1 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
State Of Charge | 99.5 % | State Of Health | 99.7 % |
Temperature | 22.4 °C | Cycle | 19 |
MOSFET | CFET = ON, DFET = ON | Reported | 2022-06-01 23:51 |