| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.299 kW | |||
|---|---|---|---|
| 07/05/2026 00:08 (2230 days) | Production | Consumption | NET Usage |
| Now | 0.226 kW | 0.525 kW | 0.299 kW |
| Today | 0.039 kWh (0.221 kW) | 0.099 kWh (0.561 kW) | 0.060 kWh (0.340 kW) |
| - This Week | 0.039 kWh | 0.099 kWh | 0.060 kWh |
| - This Month | 127.803 kWh (31.895 kWh/day) | 171.562 kWh (42.816 kWh/day) | 43.759 kWh (10.921 kWh/day) |
| - This Year | 3.738 MWh (20.203 kWh/day) | 3.458 MWh (18.693 kWh/day) | -0.279 MWh (-1.510 kWh/day) |
| Yesterday | 33.413 kWh (1.392 kW) | 43.686 kWh (1.820 kW) | 10.273 kWh (0.428 kW) |
| Last 7 Days | 209.404 kWh (29.915 kWh/day) | 245.629 kWh (35.090 kWh/day) | 36.225 kWh (5.175 kWh/day) |
| Last 30 Days (06/05/2026) | 850.412 kWh (28.347 kWh/day) | 829.833 kWh (27.661 kWh/day) | -20.579 kWh (-0.686 kWh/day) |
| Last One Year | 6.724 MWh (18.421 kWh/day) | 7.747 MWh (21.226 kWh/day) | 1.024 MWh (2.805 kWh/day) |
| Lifetime Since PTO | 39.303 MWh (17.625 kW/day) | 42.969 MWh (19.269 kW/day) | 3.666 MWh (1.644 kW/day) |
| Lifetime Since Install | 39.337 MWh | 43.549 MWh | 4.212 MWh |
| Voltage/Current | 251.4 V / 0.9 A | 251.4 V / 2.1 A | 251.4 V / 1.2 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 06/24/2023 23:38 (14.3 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 16.589 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.258 | 1.095 | 0.447 | 10.886 | 0.000 kW 1.070 kWh |
0.000 kW 6.422 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.244 | 1.044 | 0.419 | 10.226 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.260 | 1.086 | 0.443 | 10.475 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.278 | 1.094 | 0.442 | 10.624 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.265 | 1.038 | 0.410 | 9.629 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.267 | 1.065 | 0.427 | 10.530 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.263 | 1.060 | 0.393 | 9.859 | 0.000 kW 1.055 kWh |
0.000 kW 5.276 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.284 | 1.025 | 0.399 | 9.827 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.270 | 1.049 | 0.400 | 9.878 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.260 | 1.066 | 0.400 | 9.892 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.267 | 1.077 | 0.403 | 10.014 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.210 | 0.901 | 0.409 | 10.220 | 0.000 kW 0.935 kWh |
0.000 kW 3.738 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.211 | 0.898 | 0.434 | 10.433 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.219 | 0.967 | 0.454 | 10.775 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.214 | 0.973 | 0.454 | 10.795 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.384 kWh |
0.000 kW 1.153 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.230 | 1.153 | 1.134 | 9.050 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.31 V | Current/Power | -1.50 A (-79 W) |
| Remain Capacity/Energy | 389.4 Ah (19.9 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 64.9 % | State Of Health | 100.0 % |
| Run Time | 10d 19h 36m to empty | Report Date | 2023-06-24 23:57 |
|
|||
| Voltage | 53.34 V | Cell (MIN/MAX) | 3.328 V / 3.337 V (0.009 V) |
|---|---|---|---|
| Current/Power | -0.50 A (-26 W) | Runtime | 10d 19h 36m to empty |
| Remain Capacity/Energy | 129.8 Ah (6.6 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 64.9 % | State Of Health | 100.0 % |
| Temperature | 23.0 °C | Cycle | 107 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-24 23:57 |
| Voltage | 53.30 V | Cell (MIN/MAX) | 3.331 V / 3.331 V (0.000 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 89.7 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 90.2 % | State Of Health | 99.5 % |
| Temperature | 22.6 °C | Cycle | 52 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-24 23:57 |
| Voltage | 53.33 V | Cell (MIN/MAX) | 3.332 V / 3.334 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 88.1 Ah (4.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 88.6 % | State Of Health | 99.5 % |
| Temperature | 23.5 °C | Cycle | 55 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-24 23:58 |
| Voltage | 53.28 V | Cell (MIN/MAX) | 3.329 V / 3.331 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 88.3 Ah (4.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 88.8 % | State Of Health | 99.5 % |
| Temperature | 24.2 °C | Cycle | 57 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-24 23:58 |
| Voltage | 53.30 V | Cell (MIN/MAX) | 3.330 V / 3.332 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 87.3 Ah (4.5 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 88.1 % | State Of Health | 99.2 % |
| Temperature | 22.8 °C | Cycle | 55 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-24 23:58 |