| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.982 kW | |||
|---|---|---|---|
| 07/05/2026 00:28 (2230 days) | Production | Consumption | NET Usage |
| Now | 0.226 kW | 1.208 kW | 0.982 kW |
| Today | 0.114 kWh (0.225 kW) | 0.616 kWh (1.214 kW) | 0.502 kWh (0.989 kW) |
| - This Week | 0.114 kWh | 0.616 kWh | 0.502 kWh |
| - This Month | 127.878 kWh (31.804 kWh/day) | 172.079 kWh (42.797 kWh/day) | 44.201 kWh (10.993 kWh/day) |
| - This Year | 3.738 MWh (20.202 kWh/day) | 3.459 MWh (18.694 kWh/day) | -0.279 MWh (-1.507 kWh/day) |
| Yesterday | 33.413 kWh (1.392 kW) | 43.686 kWh (1.820 kW) | 10.273 kWh (0.428 kW) |
| Last 7 Days | 209.479 kWh (29.926 kWh/day) | 246.050 kWh (35.150 kWh/day) | 36.571 kWh (5.224 kWh/day) |
| Last 30 Days (06/05/2026) | 850.381 kWh (28.346 kWh/day) | 830.236 kWh (27.675 kWh/day) | -20.145 kWh (-0.671 kWh/day) |
| Last One Year | 6.724 MWh (18.421 kWh/day) | 7.748 MWh (21.227 kWh/day) | 1.024 MWh (2.806 kWh/day) |
| Lifetime Since PTO | 39.303 MWh (17.625 kW/day) | 42.970 MWh (19.269 kW/day) | 3.666 MWh (1.644 kW/day) |
| Lifetime Since Install | 39.337 MWh | 43.550 MWh | 4.212 MWh |
| Voltage/Current | 250.0 V / 0.9 A | 250.0 V / 4.8 A | 250.0 V / 3.9 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 06/15/2023 23:43 (14.7 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 24.355 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.285 | 1.646 | 1.302 | 11.332 | 0.000 kW 1.563 kWh |
0.000 kW 9.378 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.275 | 1.526 | 1.203 | 10.554 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.280 | 1.575 | 1.229 | 10.801 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.286 | 1.581 | 1.246 | 11.017 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.268 | 1.476 | 1.126 | 9.705 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.276 | 1.575 | 1.248 | 10.867 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.270 | 1.475 | 1.146 | 10.079 | 0.000 kW 1.480 kWh |
0.000 kW 7.399 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.263 | 1.450 | 1.117 | 10.012 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.263 | 1.470 | 1.151 | 10.139 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.264 | 1.491 | 1.175 | 10.181 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.267 | 1.513 | 1.200 | 10.360 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.255 | 1.561 | 1.288 | 10.905 | 0.000 kW 1.609 kWh |
0.000 kW 6.436 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.259 | 1.586 | 1.297 | 11.059 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.257 | 1.644 | 1.370 | 11.517 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.259 | 1.645 | 1.372 | 11.541 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.381 kWh |
0.000 kW 1.142 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.230 | 1.142 | 1.018 | 10.667 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.51 V | Current/Power | -10.08 A (-0.529 kW) |
| Remain Capacity/Energy | 299.4 Ah (15.3 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 49.9 % | State Of Health | 100.0 % |
| Run Time | 1d 5h 42m to empty | Report Date | 2023-06-15 23:58 |
|
|||
| Voltage | 52.50 V | Cell (MIN/MAX) | 3.275 V / 3.286 V (0.011 V) |
|---|---|---|---|
| Current/Power | -2.52 A (-132 W) | Runtime | 1d 15h 31m to empty |
| Remain Capacity/Energy | 99.8 Ah (5.1 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 49.9 % | State Of Health | 100.0 % |
| Temperature | 22.5 °C | Cycle | 105 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-15 23:58 |
| Voltage | 52.52 V | Cell (MIN/MAX) | 3.281 V / 3.283 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.70 A (-89 W) | Runtime | 1d 15h 20m to empty |
| Remain Capacity/Energy | 66.7 Ah (3.4 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 67.0 % | State Of Health | 99.5 % |
| Temperature | 22.7 °C | Cycle | 51 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-15 23:58 |
| Voltage | 52.53 V | Cell (MIN/MAX) | 3.283 V / 3.284 V (0.001 V) |
|---|---|---|---|
| Current/Power | -2.00 A (-105 W) | Runtime | 1d 7h 51m to empty |
| Remain Capacity/Energy | 63.9 Ah (3.3 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 64.2 % | State Of Health | 99.5 % |
| Temperature | 23.7 °C | Cycle | 54 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-15 23:58 |
| Voltage | 52.50 V | Cell (MIN/MAX) | 3.281 V / 3.282 V (0.001 V) |
|---|---|---|---|
| Current/Power | -2.04 A (-107 W) | Runtime | 1d 7h 7m to empty |
| Remain Capacity/Energy | 63.6 Ah (3.3 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 63.9 % | State Of Health | 99.5 % |
| Temperature | 24.4 °C | Cycle | 55 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-15 23:58 |
| Voltage | 52.50 V | Cell (MIN/MAX) | 3.281 V / 3.282 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.86 A (-97 W) | Runtime | 1d 10h 30m to empty |
| Remain Capacity/Energy | 64.1 Ah (3.3 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 64.7 % | State Of Health | 99.2 % |
| Temperature | 22.9 °C | Cycle | 54 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-15 23:58 |