| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.173 kW | |||
|---|---|---|---|
| 07/05/2026 00:57 (2230 days) | Production | Consumption | NET Usage |
| Now | 0.226 kW | 0.399 kW | 0.173 kW |
| Today | 0.221 kWh (0.225 kW) | 0.827 kWh (0.842 kW) | 0.606 kWh (0.617 kW) |
| - This Week | 0.221 kWh | 0.827 kWh | 0.606 kWh |
| - This Month | 127.985 kWh (31.675 kWh/day) | 172.290 kWh (42.640 kWh/day) | 44.305 kWh (10.965 kWh/day) |
| - This Year | 3.738 MWh (20.200 kWh/day) | 3.459 MWh (18.694 kWh/day) | -0.279 MWh (-1.506 kWh/day) |
| Yesterday | 33.413 kWh (1.392 kW) | 43.686 kWh (1.820 kW) | 10.273 kWh (0.428 kW) |
| Last 7 Days | 209.586 kWh (29.941 kWh/day) | 246.093 kWh (35.156 kWh/day) | 36.507 kWh (5.215 kWh/day) |
| Last 30 Days (06/05/2026) | 850.340 kWh (28.345 kWh/day) | 830.250 kWh (27.675 kWh/day) | -20.090 kWh (-0.670 kWh/day) |
| Last One Year | 6.724 MWh (18.422 kWh/day) | 7.748 MWh (21.227 kWh/day) | 1.024 MWh (2.805 kWh/day) |
| Lifetime Since PTO | 39.304 MWh (17.625 kW/day) | 42.970 MWh (19.269 kW/day) | 3.666 MWh (1.644 kW/day) |
| Lifetime Since Install | 39.337 MWh | 43.550 MWh | 4.212 MWh |
| Voltage/Current | 250.6 V / 0.9 A | 250.7 V / 1.6 A | 250.6 V / 0.7 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 06/02/2023 23:28 (14.6 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 29.861 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.276 | 1.980 | 2.273 | 16.349 | 0.000 kW 1.868 kWh |
0.000 kW 11.205 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.263 | 1.844 | 2.112 | 15.221 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.272 | 1.878 | 2.155 | 15.545 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.276 | 1.929 | 2.218 | 15.977 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.263 | 1.668 | 1.928 | 13.967 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.274 | 1.906 | 2.188 | 15.772 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.264 | 1.771 | 2.062 | 14.953 | 0.000 kW 1.770 kWh |
0.000 kW 8.852 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.269 | 1.762 | 1.998 | 14.469 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.263 | 1.769 | 2.021 | 14.658 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.260 | 1.759 | 2.058 | 14.902 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.266 | 1.790 | 2.103 | 15.248 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.247 | 1.976 | 2.175 | 15.681 | 0.000 kW 2.029 kWh |
0.000 kW 8.118 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.250 | 2.012 | 2.166 | 15.571 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.252 | 2.064 | 2.255 | 16.242 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.255 | 2.067 | 2.262 | 16.268 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.562 kWh |
0.000 kW 1.687 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [0] VCOP | 0.000 | 0.230 | 1.687 | 1.696 | 11.318 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.43 V | Current/Power | -7.68 A (-0.403 kW) |
| Remain Capacity/Energy | 217.5 Ah (11.1 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 36.3 % | State Of Health | 100.0 % |
| Run Time | 1d 4h 19m to empty | Report Date | 2023-06-02 23:55 |
|
|||
| Voltage | 52.43 V | Cell (MIN/MAX) | 3.271 V / 3.281 V (0.010 V) |
|---|---|---|---|
| Current/Power | -2.52 A (-132 W) | Runtime | 1d 4h 46m to empty |
| Remain Capacity/Energy | 72.5 Ah (3.7 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 36.3 % | State Of Health | 100.0 % |
| Temperature | 22.5 °C | Cycle | 104 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-02 23:55 |
| Voltage | 52.43 V | Cell (MIN/MAX) | 3.276 V / 3.277 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.31 A (-68 W) | Runtime | 1d 12h 27m to empty |
| Remain Capacity/Energy | 47.7 Ah (2.4 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 48.0 % | State Of Health | 99.5 % |
| Temperature | 22.1 °C | Cycle | 49 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-02 23:57 |
| Voltage | 52.45 V | Cell (MIN/MAX) | 3.276 V / 3.279 V (0.003 V) |
|---|---|---|---|
| Current/Power | -1.36 A (-71 W) | Runtime | 1d 8h 34m to empty |
| Remain Capacity/Energy | 44.2 Ah (2.3 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 44.4 % | State Of Health | 99.5 % |
| Temperature | 23.2 °C | Cycle | 52 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-02 23:55 |
| Voltage | 52.41 V | Cell (MIN/MAX) | 3.274 V / 3.277 V (0.003 V) |
|---|---|---|---|
| Current/Power | -1.28 A (-66 W) | Runtime | 1d 9h 57m to empty |
| Remain Capacity/Energy | 43.3 Ah (2.2 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 43.6 % | State Of Health | 99.5 % |
| Temperature | 23.9 °C | Cycle | 53 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-02 23:55 |
| Voltage | 52.42 V | Cell (MIN/MAX) | 3.274 V / 3.277 V (0.003 V) |
|---|---|---|---|
| Current/Power | -1.36 A (-71 W) | Runtime | 1d 9h 3m to empty |
| Remain Capacity/Energy | 45.0 Ah (2.3 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 45.4 % | State Of Health | 99.2 % |
| Temperature | 22.4 °C | Cycle | 52 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-06-02 23:57 |