Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.572 kW
02/01/2026 13:34 (2076 days) Production Consumption NET Usage
Now 2.902 kW 0.330 kW -2.572 kW
Today 14.182 kWh (1.043 kW) 9.346 kWh (0.688 kW) -4.836 kWh (-0.356 kW)
  - This Week 14.182 kWh (25.042 kWh/day) 9.346 kWh (16.503 kWh/day) -4.836 kWh (-8.539 kWh/day)
  - This Month 14.182 kWh (25.042 kWh/day) 9.346 kWh (16.503 kWh/day) -4.836 kWh (-8.539 kWh/day)
  - This Year 0.260 MWh (8.224 kWh/day) 0.593 MWh (18.771 kWh/day) 0.333 MWh (10.547 kWh/day)
Yesterday 17.942 kWh (0.748 kW) 16.650 kWh (0.694 kW) -1.292 kWh (-0.054 kW)
Last 7 Days 53.707 kWh (8.347 kWh/day) 100.461 kWh (15.614 kWh/day) 46.754 kWh (7.267 kWh/day)
Last 30 Days 230.120 kWh (7.818 kWh/day) 565.577 kWh (19.215 kWh/day) 335.457 kWh (11.397 kWh/day)
Last One Year 6.083 MWh (16.692 kWh/day) 7.496 MWh (20.569 kWh/day) 1.413 MWh (3.877 kWh/day)
Lifetime Since PTO 35.825 MWh (17.252 kW/day) 40.104 MWh (19.312 kW/day) 4.279 MWh (2.060 kW/day)
Lifetime Since Install 35.859 MWh 40.684 MWh 4.825 MWh
Voltage/Current 252.1 V / 11.5 A 252.1 V / 1.3 A 252.1 V / -10.2 A
Meter

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 10/09/2025 23:56 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 29.713 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.263 1.752 1.045 10.317 0.000 kW
1.706 kWh
0.000 kW
10.239 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.251 1.675 0.999 9.871
03 - 202224****** IQ7+M [5] VCOP 0.000 0.259 1.727 1.034 10.200
04 - 202232****** IQ7+ [5] VCOP 0.000 0.262 1.729 1.035 10.286
05 - 202244****** IQ7+M [5] VCOP 0.000 0.252 1.661 1.001 9.760
06 - 202245****** IQ7+M [5] VCOP 0.000 0.257 1.695 1.024 9.932
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.293 1.743 1.216 10.257 0.000 kW
1.903 kWh
0.000 kW
9.515 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.910 1.226 11.111
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.938 1.201 11.220
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.953 1.220 11.266
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.971 1.234 11.386
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.175 1.051 0.497 6.556 0.000 kW
1.118 kWh
0.000 kW
4.473 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.179 1.118 0.556 6.913
14 - 202216****** IQ7+ [5] VC-- 0.000 0.181 1.155 0.583 7.135
15 - 202245****** IQ7+M [5] VC-- 0.000 0.181 1.150 0.582 7.117
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.743 kWh
0.230 kW
5.486 kWh
17 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.486 5.520 38.483
Panel Layout Each Group Production

Charger History
Voltage PV 1.07 V Voltage Charge 52.83 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.6 °C / 27.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-10-09 23:58
voltage in/out power and energy

Battery History
Voltage 53.10 V Current/Power -6.24 A (-0.331 kW)
Remain Capacity/Energy 435.6 Ah (22.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 73.5 % State Of Health 98.9 %
Run Time 2d 21h 48m to empty Report Date 2025-10-09 23:54
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.10 V Cell (MIN/MAX) 3.313 V / 3.323 V (0.010 V)
Current/Power -1.94 A (-103 W) Runtime 3d 2h 44m to empty
Remain Capacity/Energy 145.2 Ah (7.4 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 73.5 % State Of Health 98.8 %
Temperature 24.0 °C Cycle 222
MOSFET CFET = ON, DFET = ON Reported 2025-10-09 23:54
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.313 V 3.315 V 3.314 V 3.315 V 3.317 V 3.317 V 3.318 V 3.318 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.319 V 3.320 V 3.319 V 3.321 V 3.322 V 3.322 V 3.323 V 3.322 V
pack voltage and current cell voltages
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.