Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.910 kW
07/03/2026 10:40 (2228 days) Production Consumption NET Usage
Now 3.105 kW -0.805 kW -3.910 kW
Today 7.982 kWh (0.746 kW) 16.103 kWh (1.505 kW) 8.121 kWh (0.759 kW)
  - This Week 150.856 kWh (27.705 kWh/day) 176.241 kWh (32.367 kWh/day) 25.385 kWh (4.662 kWh/day)
  - This Month 69.255 kWh (28.317 kWh/day) 102.101 kWh (41.747 kWh/day) 32.846 kWh (13.430 kWh/day)
  - This Year 3.679 MWh (20.056 kWh/day) 3.389 MWh (18.474 kWh/day) -0.290 MWh (-1.582 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 177.252 kWh (25.322 kWh/day) 208.005 kWh (29.715 kWh/day) 30.753 kWh (4.393 kWh/day)
Last 30 Days (06/03/2026) 861.902 kWh (28.730 kWh/day) 796.925 kWh (26.564 kWh/day) -64.977 kWh (-2.166 kWh/day)
Last One Year 6.717 MWh (18.402 kWh/day) 7.752 MWh (21.238 kWh/day) 1.035 MWh (2.836 kWh/day)
Lifetime Since PTO 39.245 MWh (17.611 kW/day) 42.900 MWh (19.251 kW/day) 3.655 MWh (1.640 kW/day)
Lifetime Since Install 39.279 MWh 43.480 MWh 4.201 MWh
Voltage/Current 248.7 V / 12.5 A 248.5 V / -3.2 A 248.6 V / -15.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/07/2026 23:51 (11.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.286 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.075 0.425 0.255 5.863 0.000 kW
0.412 kWh
0.000 kW
2.472 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.070 0.404 0.258 5.594
03 - 202224****** IQ7+M [5] VCOP 0.000 0.075 0.428 0.275 5.854
04 - 202232****** IQ7+ [5] VCOP 0.000 0.074 0.407 0.250 5.719
05 - 202244****** IQ7+M [5] VCOP 0.000 0.071 0.395 0.232 5.541
06 - 202245****** IQ7+M [5] VCOP 0.000 0.073 0.413 0.242 5.670
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.073 0.395 0.236 6.292 0.000 kW
0.397 kWh
0.000 kW
1.983 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.073 0.396 0.249 6.525
09 - 202217****** IQ7+ [5] VCOP 0.000 0.074 0.400 0.257 6.498
10 - 202244****** IQ7+M [5] VCOP 0.000 0.071 0.400 0.257 6.535
11 - 202224****** IQ7+M [5] VCOP 0.000 0.073 0.391 0.250 6.573
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.068 0.398 0.260 3.733 0.000 kW
0.430 kWh
0.000 kW
1.719 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.071 0.420 0.275 3.993
14 - 202216****** IQ7+ [5] VCOP 0.000 0.073 0.449 0.297 4.147
15 - 202245****** IQ7+M [5] VCOP 0.000 0.076 0.453 0.299 4.150
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 30.698 0.000 kW
0.037 kWh
0.000 kW
0.112 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.021 0.112 0.071 2.404
Panel Layout Each Group Production

Charger History
Voltage PV 1.85 V Voltage Charge 51.99 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 25.8 °C / 20.9 °C Flags 00/00/00 Energy Today 2.476 kWh @ 2026-03-07 23:55
voltage in/out power and energy

Battery History
Voltage 52.17 V Current/Power -1.80 A (-93 W)
Remain Capacity/Energy 63.7 Ah (3.3 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 11.6 % State Of Health 91.4 %
Run Time 1d 11h 22m to empty Report Date 2026-03-07 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.