Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.199 kW
05/20/2025 01:19 (1819 days) Production Consumption NET Usage
Now 0.000 kW 0.199 kW 0.199 kW
Today 0.000 kWh (0.000 kW) 0.364 kWh (0.269 kW) 0.364 kWh (0.269 kW)
  - This Week 52.668 kWh (25.605 kWh/day) 83.959 kWh (40.818 kWh/day) 31.291 kWh (15.212 kWh/day)
  - This Month 369.303 kWh (19.380 kWh/day) 333.109 kWh (17.480 kWh/day) -36.194 kWh (-1.899 kWh/day)
  - This Year 2.193 MWh (15.768 kWh/day) 2.142 MWh (15.403 kWh/day) -0.051 MWh (-0.365 kWh/day)
Yesterday 31.585 kWh (1.316 kW) 14.505 kWh (0.605 kW) -17.080 kWh (-0.712 kW)
Last 7 Days 123.478 kWh (17.642 kWh/day) 160.087 kWh (22.872 kWh/day) 36.609 kWh (5.230 kWh/day)
Last 30 Days 648.786 kWh (21.627 kWh/day) 526.700 kWh (17.557 kWh/day) -122.086 kWh (-4.070 kWh/day)
Last One Year 6.699 MWh (18.354 kWh/day) 6.323 MWh (17.324 kWh/day) -0.376 MWh (-1.029 kWh/day)
Lifetime Since PTO 31.643 MWh (17.396 kW/day) 34.094 MWh (18.743 kW/day) 2.450 MWh (1.347 kW/day)
Lifetime Since Install 31.677 MWh 34.674 MWh 2.996 MWh
Voltage/Current 252.2 V / 0.0 A 252.2 V / 0.8 A 252.2 V / 0.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/24/2021 21:40 (9.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.279 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.214 1.062 0.923 5.915 0.000 kW
1.035 kWh
0.000 kW
6.209 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.208 0.996 0.882 5.639
03 - 202224****** IQ7+M [0] ---- 0.000 0.213 1.064 0.928 5.911
04 - 202232****** IQ7+ [0] ---- 0.000 0.211 1.036 0.881 5.759
05 - 202244****** IQ7+M [0] ---- 0.000 0.211 1.020 0.910 5.815
06 - 202245****** IQ7+M [0] ---- 0.000 0.209 1.030 0.899 5.688
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.271 1.251 1.017 6.630 0.000 kW
1.244 kWh
0.000 kW
6.218 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.268 1.100 0.840 5.909
09 - 202217****** IQ7+ [0] ---- 0.000 0.269 1.341 1.091 7.031
10 - 202244****** IQ7+M [0] ---- 0.000 0.267 1.288 1.063 6.852
11 - 202224****** IQ7+M [0] ---- 0.000 0.267 1.238 0.995 6.611
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.100 0.422 0.463 3.095 0.000 kW
0.463 kWh
0.000 kW
1.853 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.102 0.481 0.496 3.352
14 - 202216****** IQ7+ [0] ---- 0.000 0.102 0.480 0.499 3.352
15 - 202245****** IQ7+M [0] ---- 0.000 0.101 0.470 0.482 3.286
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.26 V Current/Power -2.40 A (-0.128 kW)
Remain Capacity/Energy 360.0 Ah (18.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 60.0 % State Of Health 100.0 %
Run Time 6d 5h 59m to empty Report Date 2021-11-24 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.