| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 1.708 kW | |||
|---|---|---|---|
| 07/03/2026 12:40 (2228 days) | Production | Consumption | NET Usage |
| Now | 4.024 kW | 2.316 kW | -1.708 kW |
| Today | 15.137 kWh (1.192 kW) | 19.535 kWh (1.539 kW) | 4.398 kWh (0.346 kW) |
| - This Week | 158.011 kWh (28.583 kWh/day) | 179.673 kWh (32.501 kWh/day) | 21.662 kWh (3.918 kWh/day) |
| - This Month | 76.410 kWh (30.216 kWh/day) | 105.533 kWh (41.732 kWh/day) | 29.123 kWh (11.516 kWh/day) |
| - This Year | 3.686 MWh (20.085 kWh/day) | 3.392 MWh (18.484 kWh/day) | -0.294 MWh (-1.602 kWh/day) |
| Yesterday | 35.642 kWh (1.485 kW) | 43.847 kWh (1.826 kW) | 8.205 kWh (0.342 kW) |
| Last 7 Days | 181.364 kWh (25.909 kWh/day) | 209.985 kWh (29.998 kWh/day) | 28.621 kWh (4.089 kWh/day) |
| Last 30 Days (06/03/2026) | 861.034 kWh (28.701 kWh/day) | 799.430 kWh (26.648 kWh/day) | -61.604 kWh (-2.053 kWh/day) |
| Last One Year | 6.717 MWh (18.403 kWh/day) | 7.752 MWh (21.239 kWh/day) | 1.035 MWh (2.836 kWh/day) |
| Lifetime Since PTO | 39.252 MWh (17.613 kW/day) | 42.903 MWh (19.252 kW/day) | 3.651 MWh (1.638 kW/day) |
| Lifetime Since Install | 39.286 MWh | 43.483 MWh | 4.197 MWh |
| Voltage/Current | 247.8 V / 16.2 A | 247.7 V / 9.4 A | 247.8 V / -6.9 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 02/20/2026 23:36 (10.2 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 2.037 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.036 | 0.141 | 0.598 | 5.844 | 0.000 kW 0.133 kWh |
0.000 kW 0.799 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.033 | 0.130 | 0.567 | 5.544 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.035 | 0.140 | 0.592 | 5.731 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.035 | 0.133 | 0.585 | 5.655 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.031 | 0.124 | 0.553 | 5.518 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.034 | 0.131 | 0.581 | 5.733 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.031 | 0.127 | 0.559 | 6.197 | 0.000 kW 0.130 kWh |
0.000 kW 0.648 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.032 | 0.131 | 0.571 | 6.536 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.032 | 0.131 | 0.571 | 6.763 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.032 | 0.131 | 0.571 | 6.714 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.032 | 0.129 | 0.570 | 6.648 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.033 | 0.129 | 0.531 | 3.376 | 0.000 kW 0.142 kWh |
0.000 kW 0.567 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.036 | 0.140 | 0.558 | 3.143 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.037 | 0.149 | 0.579 | 2.978 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.037 | 0.150 | 0.583 | 3.673 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 8.468 | 0.000 kW 0.007 kWh |
0.000 kW 0.022 kWh |
| 17 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.009 | 0.022 | 0.183 | 2.581 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 1.04 V | Voltage Charge | 52.39 V | Current/Power | 0.00 A / 0.000 kW |
| Int/Ext Temp | 26.2 °C / 21.3 °C | Flags | 00/00/00 | Energy Today | 0.703 kWh @ 2026-02-20 23:57 |
|
|||||