Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.526 kW
07/05/2026 08:49 (2230 days) Production Consumption NET Usage
Now 0.735 kW 0.209 kW -0.526 kW
Today 2.918 kWh (0.329 kW) 6.004 kWh (0.678 kW) 3.086 kWh (0.348 kW)
  - This Week 2.918 kWh (7.908 kWh/day) 6.004 kWh (16.271 kWh/day) 3.086 kWh (8.363 kWh/day)
  - This Month 130.682 kWh (29.914 kWh/day) 177.467 kWh (40.623 kWh/day) 46.785 kWh (10.709 kWh/day)
  - This Year 3.741 MWh (20.179 kWh/day) 3.464 MWh (18.688 kWh/day) -0.276 MWh (-1.490 kWh/day)
Yesterday 33.413 kWh (1.392 kW) 43.686 kWh (1.820 kW) 10.273 kWh (0.428 kW)
Last 7 Days 210.436 kWh (30.062 kWh/day) 248.381 kWh (35.483 kWh/day) 37.945 kWh (5.421 kWh/day)
Last 30 Days (06/05/2026) 848.780 kWh (28.293 kWh/day) 831.451 kWh (27.715 kWh/day) -17.329 kWh (-0.578 kWh/day)
Last One Year 6.725 MWh (18.425 kWh/day) 7.749 MWh (21.231 kWh/day) 1.024 MWh (2.806 kWh/day)
Lifetime Since PTO 39.306 MWh (17.623 kW/day) 42.975 MWh (19.268 kW/day) 3.669 MWh (1.645 kW/day)
Lifetime Since Install 39.340 MWh 43.555 MWh 4.215 MWh
Voltage/Current 251.1 V / 2.9 A 251.0 V / 0.8 A 251.0 V / -2.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/11/2022 22:11 (8.5 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.437 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.105 0.249 1.084 6.731 0.000 kW
0.241 kWh
0.000 kW
1.443 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.105 0.238 1.023 6.395
03 - 202224****** IQ7+M [5] VCOP 0.000 0.108 0.249 1.097 6.742
04 - 202232****** IQ7+ [5] VCOP 0.000 0.106 0.243 1.064 6.533
05 - 202244****** IQ7+M [5] VCOP 0.000 0.103 0.236 1.087 6.703
06 - 202245****** IQ7+M [5] VCOP 0.000 0.103 0.229 1.058 6.495
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.098 0.192 1.133 6.875 0.000 kW
0.210 kWh
0.000 kW
1.049 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.099 0.202 1.279 7.761
09 - 202217****** IQ7+ [5] VCOP 0.000 0.103 0.222 1.415 8.437
10 - 202244****** IQ7+M [5] VCOP 0.000 0.103 0.231 1.361 8.326
11 - 202224****** IQ7+M [5] VCOP 0.000 0.102 0.202 1.288 7.973
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.096 0.236 0.512 3.554 0.000 kW
0.236 kWh
0.000 kW
0.946 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.097 0.240 0.571 3.913
14 - 202216****** IQ7+ [5] VCOP 0.000 0.097 0.237 0.575 3.916
15 - 202245****** IQ7+M [5] VCOP 0.000 0.096 0.233 0.554 3.778
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.70 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 336.9 Ah (17.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 56.1 % State Of Health 100.0 %
Run Time 9d 8h 36m to empty Report Date 2022-11-11 23:50
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.