Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.170 kW
08/25/2025 18:38 (1916 days) Production Consumption NET Usage
Now 0.317 kW 2.487 kW 2.170 kW
Today 27.459 kWh (1.473 kW) 13.788 kWh (0.740 kW) -13.671 kWh (-0.733 kW)
  - This Week 46.632 kWh (26.241 kWh/day) 36.619 kWh (20.607 kWh/day) -10.013 kWh (-5.635 kWh/day)
  - This Month 599.735 kWh (24.205 kWh/day) 721.201 kWh (29.107 kWh/day) 121.466 kWh (4.902 kWh/day)
  - This Year 4.357 MWh (18.403 kWh/day) 5.059 MWh (21.365 kWh/day) 0.701 MWh (2.962 kWh/day)
Yesterday 19.173 kWh (0.799 kW) 22.831 kWh (0.951 kW) 3.658 kWh (0.152 kW)
Last 7 Days 148.070 kWh (21.152 kWh/day) 180.014 kWh (25.715 kWh/day) 31.944 kWh (4.563 kWh/day)
Last 30 Days 705.871 kWh (23.528 kWh/day) 935.892 kWh (31.195 kWh/day) 230.021 kWh (7.667 kWh/day)
Last One Year 6.295 MWh (17.246 kWh/day) 6.975 MWh (19.109 kWh/day) 0.680 MWh (1.862 kWh/day)
Lifetime Since PTO 33.808 MWh (17.638 kW/day) 37.011 MWh (19.309 kW/day) 3.202 MWh (1.671 kW/day)
Lifetime Since Install 33.842 MWh 37.591 MWh 3.748 MWh
Voltage/Current 246.4 V / 1.3 A 246.4 V / 10.1 A 246.4 V / 8.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/16/2021 22:35 (8.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.013 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.176 0.573 0.711 4.798 0.000 kW
0.558 kWh
0.000 kW
3.345 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.173 0.536 0.676 4.552
03 - 202224****** IQ7+M [5] VCOP 0.000 0.177 0.575 0.715 4.833
04 - 202232****** IQ7+ [5] VCOP 0.000 0.177 0.553 0.694 4.727
05 - 202244****** IQ7+M [5] VCOP 0.000 0.175 0.559 0.693 4.732
06 - 202245****** IQ7+M [5] VCOP 0.000 0.172 0.550 0.672 4.579
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.221 0.670 0.814 5.664 0.000 kW
0.658 kWh
0.000 kW
3.290 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.220 0.627 0.671 5.016
09 - 202217****** IQ7+ [5] VCOP 0.000 0.221 0.675 0.837 5.987
10 - 202244****** IQ7+M [5] VCOP 0.000 0.219 0.656 0.801 5.787
11 - 202224****** IQ7+M [5] VCOP 0.000 0.221 0.661 0.771 5.539
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.105 0.334 0.367 2.159 0.000 kW
0.344 kWh
0.000 kW
1.378 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.106 0.347 0.404 2.428
14 - 202216****** IQ7+ [5] VCOP 0.000 0.108 0.351 0.409 2.447
15 - 202245****** IQ7+M [5] VCOP 0.000 0.106 0.346 0.401 2.397
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.