| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 1.252 kW | |||
|---|---|---|---|
| 07/05/2026 11:33 (2230 days) | Production | Consumption | NET Usage |
| Now | 1.622 kW | 0.370 kW | -1.252 kW |
| Today | 6.273 kWh (0.542 kW) | 9.113 kWh (0.787 kW) | 2.840 kWh (0.245 kW) |
| - This Week | 6.273 kWh (13.000 kWh/day) | 9.113 kWh (18.886 kWh/day) | 2.840 kWh (5.886 kWh/day) |
| - This Month | 134.037 kWh (29.904 kWh/day) | 180.576 kWh (40.288 kWh/day) | 46.539 kWh (10.383 kWh/day) |
| - This Year | 3.744 MWh (20.185 kWh/day) | 3.467 MWh (18.694 kWh/day) | -0.277 MWh (-1.491 kWh/day) |
| Yesterday | 33.413 kWh (1.392 kW) | 43.686 kWh (1.820 kW) | 10.273 kWh (0.428 kW) |
| Last 7 Days | 208.169 kWh (29.738 kWh/day) | 249.728 kWh (35.675 kWh/day) | 41.559 kWh (5.937 kWh/day) |
| Last 30 Days (06/05/2026) | 844.043 kWh (28.135 kWh/day) | 833.425 kWh (27.781 kWh/day) | -10.618 kWh (-0.354 kWh/day) |
| Last One Year | 6.722 MWh (18.417 kWh/day) | 7.751 MWh (21.235 kWh/day) | 1.029 MWh (2.818 kWh/day) |
| Lifetime Since PTO | 39.310 MWh (17.624 kW/day) | 42.978 MWh (19.269 kW/day) | 3.669 MWh (1.645 kW/day) |
| Lifetime Since Install | 39.343 MWh | 43.558 MWh | 4.215 MWh |
| Voltage/Current | 250.0 V / 6.5 A | 249.8 V / 1.5 A | 249.9 V / -5.0 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 08/06/2022 22:39 (13.7 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 26.707 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.296 | 1.878 | 1.517 | 11.855 | 0.000 kW 1.788 kWh |
0.000 kW 10.726 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.297 | 1.760 | 1.460 | 11.126 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.297 | 1.841 | 1.514 | 11.598 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.296 | 1.830 | 1.521 | 11.592 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.297 | 1.667 | 1.490 | 10.745 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.295 | 1.750 | 1.473 | 11.260 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.297 | 1.732 | 1.517 | 11.109 | 0.000 kW 1.742 kWh |
0.000 kW 8.711 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.297 | 1.754 | 1.511 | 10.866 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.297 | 1.716 | 1.505 | 10.868 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.297 | 1.750 | 1.526 | 11.174 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.759 | 1.500 | 11.236 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.286 | 1.841 | 1.331 | 11.386 | 0.000 kW 1.818 kWh |
0.000 kW 7.271 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.286 | 1.779 | 1.298 | 10.918 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.288 | 1.839 | 1.354 | 11.443 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.284 | 1.812 | 1.325 | 11.190 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.13 V | Current/Power | -6.88 A (-0.366 kW) |
| Remain Capacity/Energy | 498.8 Ah (25.5 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 83.1 % | State Of Health | 100.0 % |
| Run Time | 3d 0h 29m to empty | Report Date | 2022-08-06 23:57 |
|
|||
| Voltage | 53.16 V | Cell (MIN/MAX) | 3.317 V / 3.328 V (0.011 V) |
|---|---|---|---|
| Current/Power | -1.97 A (-104 W) | Runtime | 3d 12h 18m to empty |
| Remain Capacity/Energy | 166.2 Ah (8.5 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 83.1 % | State Of Health | 100.0 % |
| Temperature | 26.5 °C | Cycle | 72 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-06 23:57 |
| Voltage | 53.12 V | Cell (MIN/MAX) | 3.319 V / 3.320 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.09 A (-57 W) | Runtime | 3d 13h 6m to empty |
| Remain Capacity/Energy | 92.8 Ah (4.7 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 92.8 % | State Of Health | 100.0 % |
| Temperature | 26.0 °C | Cycle | 23 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-06 23:59 |
| Voltage | 53.16 V | Cell (MIN/MAX) | 3.321 V / 3.323 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.16 A (-61 W) | Runtime | 3d 7h 16m to empty |
| Remain Capacity/Energy | 92.1 Ah (4.7 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 92.1 % | State Of Health | 100.0 % |
| Temperature | 27.2 °C | Cycle | 24 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-06 23:59 |
| Voltage | 53.10 V | Cell (MIN/MAX) | 3.318 V / 3.319 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.18 A (-62 W) | Runtime | 3d 5h 40m to empty |
| Remain Capacity/Energy | 92.0 Ah (4.7 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 92.0 % | State Of Health | 100.0 % |
| Temperature | 27.3 °C | Cycle | 24 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-06 23:58 |
| Voltage | 53.12 V | Cell (MIN/MAX) | 3.318 V / 3.321 V (0.003 V) |
|---|---|---|---|
| Current/Power | -1.16 A (-61 W) | Runtime | 3d 7h 41m to empty |
| Remain Capacity/Energy | 92.2 Ah (4.7 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 92.5 % | State Of Health | 99.7 % |
| Temperature | 26.0 °C | Cycle | 24 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-06 23:55 |