Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.066 kW
10/29/2025 10:23 (1981 days) Production Consumption NET Usage
Now 2.200 kW 0.134 kW -2.066 kW
Today 1.567 kWh (0.151 kW) 3.594 kWh (0.346 kW) 2.027 kWh (0.195 kW)
  - This Week 45.159 kWh (13.152 kWh/day) 16.044 kWh (4.673 kWh/day) -29.115 kWh (-8.480 kWh/day)
  - This Month 456.245 kWh (16.046 kWh/day) 440.984 kWh (15.509 kWh/day) -15.261 kWh (-0.537 kWh/day)
  - This Year 5.555 MWh (18.430 kWh/day) 6.296 MWh (20.887 kWh/day) 0.740 MWh (2.457 kWh/day)
Yesterday 9.301 kWh (0.388 kW) 13.812 kWh (0.575 kW) 4.511 kWh (0.188 kW)
Last 7 Days 95.910 kWh (13.701 kWh/day) 35.599 kWh (5.086 kWh/day) -60.311 kWh (-8.616 kWh/day)
Last 30 Days 486.248 kWh (16.208 kWh/day) 466.769 kWh (15.559 kWh/day) -19.479 kWh (-0.649 kWh/day)
Last One Year 6.227 MWh (17.061 kWh/day) 7.399 MWh (20.271 kWh/day) 1.172 MWh (3.210 kWh/day)
Lifetime Since PTO 35.006 MWh (17.667 kW/day) 38.248 MWh (19.303 kW/day) 3.242 MWh (1.636 kW/day)
Lifetime Since Install 35.040 MWh 38.828 MWh 3.788 MWh
Voltage/Current 254.1 V / 8.7 A 253.9 V / 0.5 A 254.0 V / -8.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/21/2021 21:34 (8.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.748 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.211 0.999 0.968 5.699 0.000 kW
0.981 kWh
0.000 kW
5.886 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.206 0.948 0.925 5.390
03 - 202224****** IQ7+M [5] VCOP 0.000 0.211 1.006 0.964 5.685
04 - 202232****** IQ7+ [5] VCOP 0.000 0.212 0.985 0.941 5.555
05 - 202244****** IQ7+M [5] VCOP 0.000 0.209 0.992 0.954 5.598
06 - 202245****** IQ7+M [5] VCOP 0.000 0.205 0.957 0.941 5.450
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.269 1.204 1.083 6.210 0.000 kW
1.188 kWh
0.000 kW
5.938 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.268 1.114 0.925 5.504
09 - 202217****** IQ7+ [5] VCOP 0.000 0.269 1.230 1.175 6.685
10 - 202244****** IQ7+M [5] VCOP 0.000 0.265 1.190 1.138 6.533
11 - 202224****** IQ7+M [5] VCOP 0.000 0.267 1.199 1.085 6.249
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.100 0.434 0.509 3.282 0.000 kW
0.481 kWh
0.000 kW
1.924 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.101 0.503 0.533 3.475
14 - 202216****** IQ7+ [5] VCOP 0.000 0.102 0.487 0.535 3.496
15 - 202245****** IQ7+M [5] VCOP 0.000 0.100 0.499 0.519 3.402
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.80 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 326.1 Ah (16.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 54.4 % State Of Health 100.0 %
Run Time 7d 13h 10m to empty Report Date 2021-11-21 23:57
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.