Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 5.420 kW
08/25/2025 21:26 (1916 days) Production Consumption NET Usage
Now 0.000 kW 5.420 kW 5.420 kW
Today 27.655 kWh (1.290 kW) 19.368 kWh (0.903 kW) -8.287 kWh (-0.387 kW)
  - This Week 46.828 kWh (24.731 kWh/day) 42.199 kWh (22.286 kWh/day) -4.629 kWh (-2.445 kWh/day)
  - This Month 599.931 kWh (24.100 kWh/day) 726.781 kWh (29.195 kWh/day) 126.850 kWh (5.096 kWh/day)
  - This Year 4.358 MWh (18.395 kWh/day) 5.064 MWh (21.378 kWh/day) 0.707 MWh (2.983 kWh/day)
Yesterday 19.173 kWh (0.799 kW) 22.831 kWh (0.951 kW) 3.658 kWh (0.152 kW)
Last 7 Days 148.070 kWh (21.152 kWh/day) 180.014 kWh (25.715 kWh/day) 31.944 kWh (4.563 kWh/day)
Last 30 Days 705.871 kWh (23.528 kWh/day) 935.892 kWh (31.195 kWh/day) 230.021 kWh (7.667 kWh/day)
Last One Year 6.295 MWh (17.246 kWh/day) 6.975 MWh (19.109 kWh/day) 0.680 MWh (1.862 kWh/day)
Lifetime Since PTO 33.809 MWh (17.637 kW/day) 37.016 MWh (19.311 kW/day) 3.208 MWh (1.673 kW/day)
Lifetime Since Install 33.842 MWh 37.596 MWh 3.754 MWh
Voltage/Current 248.1 V / 0.0 A 247.9 V / 21.9 A 248.0 V / 21.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/11/2021 23:20 (12.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.216 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.293 1.687 1.768 9.352 0.000 kW
1.655 kWh
0.000 kW
9.928 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.290 1.653 1.693 9.052
03 - 202224****** IQ7+M [0] ---- 0.000 0.294 1.706 1.763 9.362
04 - 202232****** IQ7+ [0] ---- 0.000 0.294 1.703 1.775 9.331
05 - 202244****** IQ7+M [0] ---- 0.000 0.290 1.594 1.677 8.816
06 - 202245****** IQ7+M [0] ---- 0.000 0.289 1.585 1.646 8.797
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.733 1.827 9.401 0.000 kW
1.723 kWh
0.000 kW
8.614 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.300 1.628 1.725 9.063
09 - 202217****** IQ7+ [0] ---- 0.000 0.298 1.707 1.797 9.275
10 - 202244****** IQ7+M [0] ---- 0.000 0.299 1.776 1.878 9.561
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.769 1.888 9.592
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.229 1.435 1.464 8.116 0.000 kW
1.418 kWh
0.000 kW
5.674 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.223 1.391 1.411 7.891
14 - 202216****** IQ7+ [0] ---- 0.000 0.227 1.437 1.466 8.169
15 - 202245****** IQ7+M [0] ---- 0.000 0.226 1.412 1.437 7.877
wind 16 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.