Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.210 kW
07/23/2025 19:07 (1883 days) Production Consumption NET Usage
Now 0.282 kW 0.492 kW 0.210 kW
Today 24.276 kWh (1.269 kW) 14.764 kWh (0.772 kW) -9.512 kWh (-0.497 kW)
  - This Week 97.867 kWh (25.775 kWh/day) 154.406 kWh (40.665 kWh/day) 56.539 kWh (14.890 kWh/day)
  - This Month 549.724 kWh (24.113 kWh/day) 888.308 kWh (38.965 kWh/day) 338.584 kWh (14.852 kWh/day)
  - This Year 3.579 MWh (17.564 kWh/day) 4.016 MWh (19.704 kWh/day) 0.436 MWh (2.140 kWh/day)
Yesterday 21.011 kWh (0.875 kW) 20.126 kWh (0.838 kW) -0.885 kWh (-0.037 kW)
Last 7 Days 168.523 kWh (24.075 kWh/day) 277.507 kWh (39.645 kWh/day) 108.984 kWh (15.569 kWh/day)
Last 30 Days 717.715 kWh (23.924 kWh/day) 1178.334 kWh (39.278 kWh/day) 460.619 kWh (15.354 kWh/day)
Last One Year 6.263 MWh (17.158 kWh/day) 6.646 MWh (18.209 kWh/day) 0.384 MWh (1.051 kWh/day)
Lifetime Since PTO 33.030 MWh (17.534 kW/day) 35.968 MWh (19.093 kW/day) 2.937 MWh (1.559 kW/day)
Lifetime Since Install 33.064 MWh 36.547 MWh 3.483 MWh
Voltage/Current 250.4 V / 1.1 A 250.3 V / 2.0 A 250.4 V / 0.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/20/2025 23:36 (10.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.037 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.237 0.859 1.329 6.685 0.000 kW
0.825 kWh
0.000 kW
4.950 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.228 0.803 1.253 6.305
03 - 202224****** IQ7+M [5] VCOP 0.000 0.236 0.843 1.305 6.546
04 - 202232****** IQ7+ [5] VCOP 0.000 0.233 0.839 1.307 6.558
05 - 202244****** IQ7+M [5] VCOP 0.000 0.227 0.791 1.251 6.403
06 - 202245****** IQ7+M [5] VCOP 0.000 0.232 0.817 1.281 6.569
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.247 0.644 1.294 6.680 0.000 kW
0.776 kWh
0.000 kW
3.880 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.250 0.756 1.399 7.311
09 - 202217****** IQ7+ [5] VCOP 0.000 0.251 0.838 1.435 7.657
10 - 202244****** IQ7+M [5] VCOP 0.000 0.247 0.832 1.427 7.609
11 - 202224****** IQ7+M [5] VCOP 0.000 0.251 0.810 1.426 7.522
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.172 0.765 0.917 3.895 0.000 kW
0.802 kWh
0.000 kW
3.207 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.175 0.795 0.952 4.199
14 - 202216****** IQ7+ [5] VCOP 0.000 0.178 0.823 0.979 4.342
15 - 202245****** IQ7+M [5] VCOP 0.000 0.174 0.825 0.974 4.351
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 0.51 V Voltage Charge 52.78 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.8 °C / 23.3 °C Flags 00/00/00 Energy Today 5.244 kWh @ 2025-02-20 23:59
voltage in/out power and energy

Battery History
Voltage 53.04 V Current/Power -6.42 A (-0.340 kW)
Remain Capacity/Energy 456.0 Ah (23.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 76.9 % State Of Health 98.9 %
Run Time 2d 23h 1m to empty Report Date 2025-02-20 23:56
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.04 V Cell (MIN/MAX) 3.307 V / 3.320 V (0.013 V)
Current/Power -1.99 A (-105 W) Runtime 3d 4h 23m to empty
Remain Capacity/Energy 152.0 Ah (7.8 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 76.9 % State Of Health 98.8 %
Temperature 15.0 °C Cycle 183
MOSFET CFET = ON, DFET = ON Reported 2025-02-20 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.307 V 3.310 V 3.311 V 3.311 V 3.313 V 3.311 V 3.313 V 3.315 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.317 V 3.315 V 3.316 V 3.317 V 3.319 V 3.318 V 3.320 V 3.320 V
pack voltage and current cell voltages