Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.198 kW
06/12/2025 12:10 (1842 days) Production Consumption NET Usage
Now 3.638 kW 2.440 kW -1.198 kW
Today 11.100 kWh (0.910 kW) 7.067 kWh (0.579 kW) -4.033 kWh (-0.331 kW)
  - This Week 79.177 kWh (17.561 kWh/day) 64.475 kWh (14.300 kWh/day) -14.702 kWh (-3.261 kWh/day)
  - This Month 258.270 kWh (22.442 kWh/day) 200.225 kWh (17.399 kWh/day) -58.045 kWh (-5.044 kWh/day)
  - This Year 2.659 MWh (16.365 kWh/day) 2.554 MWh (15.717 kWh/day) -0.105 MWh (-0.648 kWh/day)
Yesterday 30.628 kWh (1.276 kW) 18.400 kWh (0.767 kW) -12.228 kWh (-0.509 kW)
Last 7 Days 134.953 kWh (19.279 kWh/day) 131.121 kWh (18.731 kWh/day) -3.832 kWh (-0.547 kWh/day)
Last 30 Days 579.203 kWh (19.307 kWh/day) 565.706 kWh (18.857 kWh/day) -13.497 kWh (-0.450 kWh/day)
Last One Year 6.481 MWh (17.757 kWh/day) 6.259 MWh (17.147 kWh/day) -0.223 MWh (-0.610 kWh/day)
Lifetime Since PTO 32.110 MWh (17.427 kW/day) 34.506 MWh (18.728 kW/day) 2.396 MWh (1.300 kW/day)
Lifetime Since Install 32.144 MWh 35.086 MWh 2.942 MWh
Voltage/Current 249.7 V / 14.6 A 249.8 V / 9.8 A 249.7 V / -4.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/22/2021 23:25 (12.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.801 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.285 1.959 1.996 9.369 0.000 kW
1.933 kWh
0.000 kW
11.601 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.931 1.966 9.161
03 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.979 2.011 9.385
04 - 202232****** IQ7+ [5] VCOP 0.000 0.287 1.986 2.016 9.360
05 - 202244****** IQ7+M [5] VCOP 0.000 0.283 1.879 1.906 8.912
06 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.867 1.893 8.913
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 2.056 2.083 9.490 0.000 kW
2.040 kWh
0.000 kW
10.200 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.905 1.942 8.866
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 2.048 2.076 9.513
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.100 2.124 9.698
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.091 2.116 9.651
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.214 1.512 1.537 7.364 0.000 kW
1.500 kWh
0.000 kW
6.000 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.213 1.467 1.487 7.177
14 - 202216****** IQ7+ [5] VCOP 0.000 0.213 1.523 1.545 7.413
15 - 202245****** IQ7+M [5] VCOP 0.000 0.211 1.497 1.518 7.276
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 522.6 Ah (26.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 88.4 % State Of Health 98.5 %
Run Time 14d 12h 24m to empty Report Date 2021-03-22 23:59
voltag, current for each battery pack voltage, current, and SOC ;

Voltage 53.27 V Cell (MIN/MAX) 3.325 V / 3.333 V (0.008 V)
Current/Power -0.50 A (-26 W) Runtime 14d 12h 24m to empty
Remain Capacity/Energy 174.2 Ah (8.9 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 88.4 % State Of Health 98.5 %
Temperature 22.0 °C Cycle 34
MOSFET CFET = ON, DFET = ON Reported 2021-03-22 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.325 V 3.325 V 3.325 V 3.326 V 3.327 V 3.328 V 3.328 V 3.328 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.329 V 3.329 V 3.330 V 3.331 V 3.332 V 3.330 V 3.333 V 3.333 V
pack voltage and current cell voltages