Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.444 kW
08/26/2025 03:41 (1917 days) Production Consumption NET Usage
Now 0.000 kW 0.444 kW 0.444 kW
Today 0.000 kWh (0.000 kW) 2.111 kWh (0.570 kW) 2.111 kWh (0.570 kW)
  - This Week 46.828 kWh (21.740 kWh/day) 47.422 kWh (22.015 kWh/day) 0.594 kWh (0.276 kWh/day)
  - This Month 599.931 kWh (23.850 kWh/day) 732.004 kWh (29.101 kWh/day) 132.073 kWh (5.251 kWh/day)
  - This Year 4.358 MWh (18.375 kWh/day) 5.070 MWh (21.377 kWh/day) 0.712 MWh (3.002 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.809 MWh (17.635 kW/day) 37.022 MWh (19.311 kW/day) 3.213 MWh (1.676 kW/day)
Lifetime Since Install 33.842 MWh 37.602 MWh 3.759 MWh
Voltage/Current 253.9 V / 0.0 A 253.9 V / 1.7 A 253.9 V / 1.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/26/2021 20:10 (14.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.547 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.271 2.002 2.179 13.259 0.000 kW
1.959 kWh
0.000 kW
11.753 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.266 1.955 2.137 12.806
03 - 202224****** IQ7+M [0] ---- 0.000 0.269 1.989 2.175 12.952
04 - 202232****** IQ7+ [0] ---- 0.000 0.274 1.998 2.183 13.094
05 - 202244****** IQ7+M [0] ---- 0.000 0.269 1.856 2.117 12.088
06 - 202245****** IQ7+M [0] ---- 0.000 0.265 1.953 2.139 12.866
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.273 1.891 2.064 12.151 0.000 kW
1.890 kWh
0.000 kW
9.449 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.272 1.871 2.112 12.304
09 - 202217****** IQ7+ [0] ---- 0.000 0.274 1.897 2.099 12.296
10 - 202244****** IQ7+M [0] ---- 0.000 0.272 1.897 2.133 12.488
11 - 202224****** IQ7+M [0] ---- 0.000 0.273 1.895 2.145 12.513
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.242 1.848 1.953 12.974 0.000 kW
1.836 kWh
0.000 kW
7.345 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.243 1.799 1.875 12.569
14 - 202216****** IQ7+ [0] ---- 0.000 0.243 1.858 1.959 13.004
15 - 202245****** IQ7+M [0] ---- 0.000 0.241 1.839 1.937 12.872
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.