Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.022 kW
06/07/2025 07:52 (1837 days) Production Consumption NET Usage
Now 0.496 kW 0.474 kW -0.022 kW
Today 0.596 kWh (0.076 kW) 3.858 kWh (0.489 kW) 3.262 kWh (0.414 kW)
  - This Week 165.857 kWh (26.206 kWh/day) 119.403 kWh (18.866 kWh/day) -46.454 kWh (-7.340 kWh/day)
  - This Month 165.857 kWh (26.206 kWh/day) 119.403 kWh (18.866 kWh/day) -46.454 kWh (-7.340 kWh/day)
  - This Year 2.567 MWh (16.316 kWh/day) 2.473 MWh (15.721 kWh/day) -0.094 MWh (-0.595 kWh/day)
Yesterday 25.293 kWh (1.053 kW) 27.492 kWh (1.144 kW) 2.199 kWh (0.092 kW)
Last 7 Days 181.940 kWh (25.989 kWh/day) 148.542 kWh (21.219 kWh/day) -33.398 kWh (-4.771 kWh/day)
Last 30 Days 618.729 kWh (20.624 kWh/day) 570.095 kWh (19.003 kWh/day) -48.634 kWh (-1.621 kWh/day)
Last One Year 6.547 MWh (17.937 kWh/day) 6.282 MWh (17.211 kWh/day) -0.265 MWh (-0.726 kWh/day)
Lifetime Since PTO 32.018 MWh (17.426 kW/day) 34.425 MWh (18.737 kW/day) 2.407 MWh (1.310 kW/day)
Lifetime Since Install 32.052 MWh 35.005 MWh 2.953 MWh
Voltage/Current 248.9 V / 2.0 A 249.0 V / 1.9 A 249.0 V / -0.1 A
Meter Accumulated Grid Votlage Power

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_panel_inc.php on line 411

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/01/2021 23:00 (10.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.555 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.123 0.386 0.267 5.556 0.000 kW
0.373 kWh
0.000 kW
2.241 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.122 0.364 0.247 5.261
03 - 202224****** IQ7+M [5] VCOP 0.000 0.115 0.384 0.263 5.413
04 - 202232****** IQ7+ [5] VCOP 0.000 0.118 0.380 0.261 5.390
05 - 202244****** IQ7+M [5] VCOP 0.000 0.120 0.356 0.239 5.652
06 - 202245****** IQ7+M [5] VCOP 0.000 0.120 0.370 0.252 5.700
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.139 0.399 0.239 6.149 0.000 kW
0.397 kWh
0.000 kW
1.987 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.142 0.399 0.237 5.651
09 - 202217****** IQ7+ [5] VCOP 0.000 0.141 0.370 0.241 6.404
10 - 202244****** IQ7+M [5] VCOP 0.000 0.139 0.412 0.246 6.737
11 - 202224****** IQ7+M [5] VCOP 0.000 0.135 0.407 0.239 6.398
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.099 0.329 0.268 3.829 0.000 kW
0.332 kWh
0.000 kW
1.327 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.098 0.330 0.270 3.769
14 - 202216****** IQ7+ [5] VCOP 0.000 0.099 0.337 0.274 3.795
15 - 202245****** IQ7+M [5] VCOP 0.000 0.098 0.331 0.269 3.798
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.96 V Current/Power 28.73 A (1.550 kW)
Remain Capacity/Energy 515.7 Ah (26.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 87.3 % State Of Health 98.5 %
Run Time 2h 37m to full Report Date 2021-03-01 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 54.00 V Cell (MIN/MAX) 3.371 V / 3.381 V (0.010 V)
Current/Power 8.50 A (0.459 kW) Runtime 2h 57m to full
Remain Capacity/Energy 171.9 Ah (8.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 87.3 % State Of Health 98.5 %
Temperature 20.0 °C Cycle 33
MOSFET CFET = ON, DFET = ON Reported 2021-03-01 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.371 V 3.373 V 3.371 V 3.374 V 3.373 V 3.374 V 3.375 V 3.373 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.373 V 3.378 V 3.377 V 3.376 V 3.376 V 3.377 V 3.381 V 3.376 V
pack voltage and current cell voltages
pack temperature