Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.119 kW
05/22/2025 15:37 (1821 days) Production Consumption NET Usage
Now 0.359 kW 0.240 kW -0.119 kW
Today 4.876 kWh (0.312 kW) 6.504 kWh (0.416 kW) 1.628 kWh (0.104 kW)
  - This Week 92.235 kWh (19.826 kWh/day) 114.660 kWh (24.646 kWh/day) 22.425 kWh (4.820 kWh/day)
  - This Month 408.870 kWh (18.884 kWh/day) 363.810 kWh (16.803 kWh/day) -45.060 kWh (-2.081 kWh/day)
  - This Year 2.232 MWh (15.758 kWh/day) 2.173 MWh (15.337 kWh/day) -0.060 MWh (-0.421 kWh/day)
Yesterday 3.735 kWh (0.156 kW) 13.621 kWh (0.568 kW) 9.886 kWh (0.412 kW)
Last 7 Days 141.260 kWh (20.182 kWh/day) 157.761 kWh (22.540 kWh/day) 16.501 kWh (2.358 kWh/day)
Last 30 Days 640.464 kWh (21.349 kWh/day) 524.106 kWh (17.471 kWh/day) -116.358 kWh (-3.879 kWh/day)
Last One Year 6.671 MWh (18.278 kWh/day) 6.320 MWh (17.316 kWh/day) -0.351 MWh (-0.962 kWh/day)
Lifetime Since PTO 31.683 MWh (17.392 kW/day) 34.125 MWh (18.733 kW/day) 2.441 MWh (1.340 kW/day)
Lifetime Since Install 31.717 MWh 34.704 MWh 2.988 MWh
Voltage/Current 250.7 V / 1.4 A 250.8 V / 1.0 A 250.8 V / -0.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/09/2021 21:52 (9.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.360 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.236 0.820 0.644 4.192 0.000 kW
0.789 kWh
0.000 kW
4.732 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.228 0.755 0.584 3.883
03 - 202224****** IQ7+M [5] VCOP 0.000 0.231 0.752 0.574 3.885
04 - 202232****** IQ7+ [5] VCOP 0.000 0.234 0.731 0.530 3.710
05 - 202244****** IQ7+M [5] VCOP 0.000 0.228 0.828 0.628 4.163
06 - 202245****** IQ7+M [5] VCOP 0.000 0.229 0.846 0.658 4.292
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 0.959 0.729 5.192 0.000 kW
0.956 kWh
0.000 kW
4.780 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.292 0.794 0.610 4.519
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.055 0.799 5.514
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.040 0.783 5.470
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 0.932 0.721 5.133
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.111 0.438 0.404 2.143 0.000 kW
0.462 kWh
0.000 kW
1.848 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.120 0.475 0.423 2.354
14 - 202216****** IQ7+ [5] VCOP 0.000 0.118 0.475 0.424 2.354
15 - 202245****** IQ7+M [5] VCOP 0.000 0.114 0.461 0.412 2.295
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Battery History
Voltage 53.22 V Current/Power 166.21 A (8.845 kW)
Remain Capacity/Energy 479.4 Ah (24.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 81.1 % State Of Health 98.5 %
Run Time 40m to full Report Date 2021-01-09 23:35
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.22 V Cell (MIN/MAX) 3.320 V / 3.330 V (0.010 V)
Current/Power -0.26 A (-13 W) Runtime 26d 0h 13m to empty
Remain Capacity/Energy 159.8 Ah (8.2 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 81.1 % State Of Health 98.5 %
Temperature 18.5 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-09 23:35
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.320 V 3.322 V 3.322 V 3.323 V 3.323 V 3.324 V 3.325 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.327 V 3.327 V 3.328 V 3.329 V 3.330 V 3.330 V 3.330 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -