Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.095 kW
05/22/2025 17:43 (1821 days) Production Consumption NET Usage
Now 0.325 kW 0.420 kW 0.095 kW
Today 5.828 kWh (0.328 kW) 7.390 kWh (0.416 kW) 1.562 kWh (0.088 kW)
  - This Week 93.187 kWh (19.659 kWh/day) 115.546 kWh (24.375 kWh/day) 22.359 kWh (4.717 kWh/day)
  - This Month 409.822 kWh (18.852 kWh/day) 364.696 kWh (16.776 kWh/day) -45.126 kWh (-2.076 kWh/day)
  - This Year 2.233 MWh (15.755 kWh/day) 2.173 MWh (15.334 kWh/day) -0.060 MWh (-0.421 kWh/day)
Yesterday 3.735 kWh (0.156 kW) 13.621 kWh (0.568 kW) 9.886 kWh (0.412 kW)
Last 7 Days 141.260 kWh (20.182 kWh/day) 157.761 kWh (22.540 kWh/day) 16.501 kWh (2.358 kWh/day)
Last 30 Days 640.464 kWh (21.349 kWh/day) 524.106 kWh (17.471 kWh/day) -116.358 kWh (-3.879 kWh/day)
Last One Year 6.671 MWh (18.278 kWh/day) 6.320 MWh (17.316 kWh/day) -0.351 MWh (-0.962 kWh/day)
Lifetime Since PTO 31.684 MWh (17.392 kW/day) 34.125 MWh (18.732 kW/day) 2.441 MWh (1.340 kW/day)
Lifetime Since Install 31.718 MWh 34.705 MWh 2.987 MWh
Voltage/Current 251.7 V / 1.3 A 251.7 V / 1.7 A 251.7 V / 0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/08/2021 21:48 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.922 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.208 0.644 1.001 3.926 0.000 kW
0.603 kWh
0.000 kW
3.617 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.192 0.584 0.940 3.644
03 - 202224****** IQ7+M [5] VCOP 0.000 0.178 0.574 0.931 3.676
04 - 202232****** IQ7+ [5] VCOP 0.000 0.179 0.530 0.886 3.553
05 - 202244****** IQ7+M [5] VCOP 0.000 0.211 0.628 1.027 3.880
06 - 202245****** IQ7+M [5] VCOP 0.000 0.206 0.658 1.039 3.999
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.256 0.729 1.308 4.805 0.000 kW
0.729 kWh
0.000 kW
3.643 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.254 0.610 1.138 4.202
09 - 202217****** IQ7+ [5] VCOP 0.000 0.258 0.799 1.424 5.103
10 - 202244****** IQ7+M [5] VCOP 0.000 0.259 0.783 1.406 5.073
11 - 202224****** IQ7+M [5] VCOP 0.000 0.255 0.721 1.295 4.741
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.114 0.404 0.355 2.083 0.000 kW
0.416 kWh
0.000 kW
1.662 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.112 0.423 0.433 2.277
14 - 202216****** IQ7+ [5] VCOP 0.000 0.113 0.424 0.428 2.278
15 - 202245****** IQ7+M [5] VCOP 0.000 0.111 0.412 0.415 2.222
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Battery History
Voltage 53.24 V Current/Power 166.27 A (8.852 kW)
Remain Capacity/Energy 498.0 Ah (25.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 84.3 % State Of Health 98.5 %
Run Time 33m to full Report Date 2021-01-08 23:44
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.24 V Cell (MIN/MAX) 3.321 V / 3.331 V (0.010 V)
Current/Power -0.26 A (-13 W) Runtime 26d 21h 54m to empty
Remain Capacity/Energy 166.0 Ah (8.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 84.3 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-08 23:44
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.323 V 3.323 V 3.324 V 3.325 V 3.326 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.328 V 3.328 V 3.329 V 3.330 V 3.331 V 3.331 V 3.331 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -