Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 6.922 kW
07/08/2025 21:28 (1868 days) Production Consumption NET Usage
Now 0.000 kW 6.922 kW 6.922 kW
Today 25.246 kWh (1.174 kW) 36.353 kWh (1.691 kW) 11.107 kWh (0.517 kW)
  - This Week 74.549 kWh (25.741 kWh/day) 147.699 kWh (50.998 kWh/day) 73.150 kWh (25.258 kWh/day)
  - This Month 204.258 kWh (25.869 kWh/day) 316.425 kWh (40.075 kWh/day) 112.167 kWh (14.206 kWh/day)
  - This Year 3.234 MWh (17.120 kWh/day) 3.444 MWh (18.231 kWh/day) 0.210 MWh (1.110 kWh/day)
Yesterday 17.671 kWh (0.736 kW) 62.190 kWh (2.592 kW) 44.519 kWh (1.855 kW)
Last 7 Days 179.012 kWh (25.573 kWh/day) 280.072 kWh (40.010 kWh/day) 101.060 kWh (14.437 kWh/day)
Last 30 Days 628.494 kWh (20.950 kWh/day) 917.638 kWh (30.588 kWh/day) 289.144 kWh (9.638 kWh/day)
Last One Year 6.308 MWh (17.282 kWh/day) 6.469 MWh (17.724 kWh/day) 0.161 MWh (0.442 kWh/day)
Lifetime Since PTO 32.685 MWh (17.489 kW/day) 35.396 MWh (18.939 kW/day) 2.711 MWh (1.450 kW/day)
Lifetime Since Install 32.719 MWh 35.976 MWh 3.257 MWh
Voltage/Current 247.7 V / 0.0 A 247.5 V / 28.0 A 247.6 V / 28.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/12/2021 22:07 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.814 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.237 0.996 0.389 5.161 0.000 kW
0.962 kWh
0.000 kW
5.774 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.230 0.938 0.354 4.788
03 - 202224****** IQ7+M [0] V--- 0.000 0.234 0.933 0.377 4.815
04 - 202232****** IQ7+ [0] ---- 0.000 0.234 0.901 0.382 4.658
05 - 202244****** IQ7+M [0] ---- 0.000 0.230 0.996 0.346 5.133
06 - 202245****** IQ7+M [0] ---- 0.000 0.230 1.009 0.365 5.249
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.289 1.242 0.376 6.250 0.000 kW
1.246 kWh
0.000 kW
6.228 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.288 1.092 0.369 5.454
09 - 202217****** IQ7+ [0] ---- 0.000 0.293 1.332 0.383 6.703
10 - 202244****** IQ7+M [0] ---- 0.000 0.288 1.329 0.386 6.644
11 - 202224****** IQ7+M [0] ---- 0.000 0.290 1.233 0.375 6.174
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.092 0.415 0.336 2.659 0.000 kW
0.453 kWh
0.000 kW
1.812 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.107 0.474 0.339 2.917
14 - 202216****** IQ7+ [0] ---- 0.000 0.109 0.469 0.345 2.915
15 - 202245****** IQ7+M [0] ---- 0.000 0.105 0.455 0.337 2.840
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.74 V Current/Power 167.73 A (9.014 kW)
Remain Capacity/Energy 524.4 Ah (26.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 88.7 % State Of Health 98.5 %
Run Time 23m to full Report Date 2021-01-12 23:58
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.74 V Cell (MIN/MAX) 3.351 V / 3.366 V (0.015 V)
Current/Power -0.26 A (-13 W) Runtime 28d 8h 9m to empty
Remain Capacity/Energy 174.8 Ah (8.9 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 88.7 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-12 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.360 V 3.351 V 3.360 V 3.352 V 3.361 V 3.353 V 3.354 V 3.364 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.361 V 3.353 V 3.363 V 3.355 V 3.364 V 3.356 V 3.365 V 3.366 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -