Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.449 kW
07/08/2025 22:27 (1868 days) Production Consumption NET Usage
Now 0.000 kW 2.449 kW 2.449 kW
Today 25.246 kWh (1.123 kW) 38.216 kWh (1.700 kW) 12.970 kWh (0.577 kW)
  - This Week 74.549 kWh (25.381 kWh/day) 149.562 kWh (50.920 kWh/day) 75.013 kWh (25.539 kWh/day)
  - This Month 204.258 kWh (25.735 kWh/day) 318.288 kWh (40.103 kWh/day) 114.030 kWh (14.367 kWh/day)
  - This Year 3.234 MWh (17.117 kWh/day) 3.446 MWh (18.236 kWh/day) 0.212 MWh (1.120 kWh/day)
Yesterday 17.671 kWh (0.736 kW) 62.190 kWh (2.592 kW) 44.519 kWh (1.855 kW)
Last 7 Days 179.012 kWh (25.573 kWh/day) 280.072 kWh (40.010 kWh/day) 101.060 kWh (14.437 kWh/day)
Last 30 Days 628.494 kWh (20.950 kWh/day) 917.638 kWh (30.588 kWh/day) 289.144 kWh (9.638 kWh/day)
Last One Year 6.308 MWh (17.282 kWh/day) 6.469 MWh (17.724 kWh/day) 0.161 MWh (0.442 kWh/day)
Lifetime Since PTO 32.685 MWh (17.488 kW/day) 35.398 MWh (18.940 kW/day) 2.713 MWh (1.451 kW/day)
Lifetime Since Install 32.719 MWh 35.977 MWh 3.259 MWh
Voltage/Current 247.8 V / 0.0 A 247.7 V / 9.9 A 247.8 V / 9.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/17/2020 21:39 (5.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.282 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.000 0.000 0.190 3.475 0.000 kW
0.001 kWh
0.000 kW
0.004 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.000 0.000 0.179 3.356
03 - 202224****** IQ7+M [0] V--- 0.000 0.002 0.001 0.189 3.314
04 - 202232****** IQ7+ [0] ---- 0.000 0.002 0.001 0.186 3.156
05 - 202244****** IQ7+M [0] ---- 0.000 0.002 0.001 0.174 3.561
06 - 202245****** IQ7+M [0] ---- 0.000 0.002 0.001 0.180 3.632
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.005 0.002 0.168 4.225 0.000 kW
0.005 kWh
0.000 kW
0.023 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.004 0.001 0.042 0.042
09 - 202217****** IQ7+ [0] ---- 0.000 0.005 0.007 0.170 4.528
10 - 202244****** IQ7+M [0] ---- 0.000 0.006 0.008 0.173 4.481
11 - 202224****** IQ7+M [0] ---- 0.000 0.005 0.005 0.168 4.148
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.016 0.050 0.191 1.778 0.000 kW
0.064 kWh
0.000 kW
0.255 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.013 0.040 0.192 1.950
14 - 202216****** IQ7+ [0] ---- 0.000 0.012 0.036 0.196 1.952
15 - 202245****** IQ7+M [0] ---- 0.000 0.050 0.130 0.192 1.896
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.49 V Current/Power 163.92 A (8.604 kW)
Remain Capacity/Energy 365.4 Ah (18.7 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 61.8 % State Of Health 98.5 %
Run Time 1h 22m to full Report Date 2020-12-17 23:27
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.49 V Cell (MIN/MAX) 3.275 V / 3.285 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 10d 3h 7m to empty
Remain Capacity/Energy 121.8 Ah (6.2 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 61.8 % State Of Health 98.5 %
Temperature 22.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-17 23:27
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.275 V 3.276 V 3.276 V 3.277 V 3.278 V 3.278 V 3.279 V 3.280 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.281 V 3.281 V 3.282 V 3.282 V 3.283 V 3.284 V 3.284 V 3.285 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -