Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.216 kW
05/23/2025 16:02 (1822 days) Production Consumption NET Usage
Now 0.618 kW 0.402 kW -0.216 kW
Today 10.846 kWh (0.676 kW) 6.829 kWh (0.426 kW) -4.017 kWh (-0.250 kW)
  - This Week 104.210 kWh (18.380 kWh/day) 127.694 kWh (22.522 kWh/day) 23.484 kWh (4.142 kWh/day)
  - This Month 420.845 kWh (18.565 kWh/day) 376.844 kWh (16.624 kWh/day) -44.001 kWh (-1.941 kWh/day)
  - This Year 2.244 MWh (15.730 kWh/day) 2.186 MWh (15.319 kWh/day) -0.059 MWh (-0.410 kWh/day)
Yesterday 6.005 kWh (0.250 kW) 12.709 kWh (0.529 kW) 6.704 kWh (0.279 kW)
Last 7 Days 134.531 kWh (19.219 kWh/day) 156.455 kWh (22.351 kWh/day) 21.924 kWh (3.132 kWh/day)
Last 30 Days 619.275 kWh (20.642 kWh/day) 521.298 kWh (17.376 kWh/day) -97.977 kWh (-3.266 kWh/day)
Last One Year 6.646 MWh (18.208 kWh/day) 6.300 MWh (17.261 kWh/day) -0.346 MWh (-0.947 kWh/day)
Lifetime Since PTO 31.695 MWh (17.389 kW/day) 34.138 MWh (18.729 kW/day) 2.443 MWh (1.340 kW/day)
Lifetime Since Install 31.729 MWh 34.718 MWh 2.989 MWh
Voltage/Current 250.8 V / 2.5 A 250.8 V / 1.6 A 250.8 V / -0.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/25/2020 21:59 (10.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.520 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.201 0.667 0.138 4.338 0.000 kW
0.657 kWh
0.000 kW
3.940 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.199 0.656 0.134 4.282
03 - 202224****** IQ7+M [5] VCOP 0.000 0.203 0.667 0.139 4.361
04 - 202232****** IQ7+ [5] VCOP 0.000 0.202 0.656 0.135 4.312
05 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.649 0.134 4.296
06 - 202245****** IQ7+M [5] VCOP 0.000 0.202 0.647 0.134 4.294
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.200 0.614 0.122 4.546 0.000 kW
0.613 kWh
0.000 kW
3.063 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.177 0.538 0.123 4.338
09 - 202217****** IQ7+ [5] VCOP 0.000 0.203 0.642 0.123 4.693
10 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.644 0.124 4.719
11 - 202224****** IQ7+M [5] VCOP 0.000 0.200 0.625 0.123 4.646
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.172 0.626 0.133 3.234 0.000 kW
0.629 kWh
0.000 kW
2.517 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.171 0.629 0.133 3.281
14 - 202216****** IQ7+ [5] VCOP 0.000 0.171 0.636 0.135 3.330
15 - 202245****** IQ7+M [5] VCOP 0.000 0.170 0.627 0.133 3.273
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Battery History
Voltage 56.03 V Current/Power 175.01 A (9.806 kW)
Remain Capacity/Energy 530.4 Ah (27.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 89.7 % State Of Health 98.5 %
Run Time 20m to full Report Date 2020-10-25 16:26
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.03 V Cell (MIN/MAX) 3.490 V / 3.509 V (0.019 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 176.8 Ah (9.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 89.7 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-10-25 16:26
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.498 V 3.490 V 3.498 V 3.499 V 3.501 V 3.504 V 3.504 V 3.503 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.499 V 3.505 V 3.505 V 3.504 V 3.505 V 3.499 V 3.508 V 3.509 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -