Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.540 kW
05/20/2026 21:29 (2184 days) Production Consumption NET Usage
Now 0.000 kW 2.540 kW 2.540 kW
Today 25.684 kWh (1.194 kW) 40.238 kWh (1.870 kW) 14.554 kWh (0.676 kW)
  - This Week 116.795 kWh (29.978 kWh/day) 127.218 kWh (32.653 kWh/day) 10.423 kWh (2.675 kWh/day)
  - This Month 518.611 kWh (26.067 kWh/day) 326.940 kWh (16.433 kWh/day) -191.671 kWh (-9.634 kWh/day)
  - This Year 2.472 MWh (17.668 kWh/day) 2.387 MWh (17.060 kWh/day) -0.085 MWh (-0.608 kWh/day)
Yesterday 28.907 kWh (1.205 kW) 38.153 kWh (1.591 kW) 9.246 kWh (0.386 kW)
Last 7 Days 194.018 kWh (27.717 kWh/day) 159.784 kWh (22.826 kWh/day) -34.234 kWh (-4.891 kWh/day)
Last 30 Days (04/20/2026) 722.358 kWh (24.079 kWh/day) 423.885 kWh (14.130 kWh/day) -298.473 kWh (-9.949 kWh/day)
Last One Year 6.363 MWh (17.433 kWh/day) 7.794 MWh (21.354 kWh/day) 1.431 MWh (3.922 kWh/day)
Lifetime Since PTO 38.037 MWh (17.409 kW/day) 41.897 MWh (19.176 kW/day) 3.860 MWh (1.767 kW/day)
Lifetime Since Install 38.071 MWh 42.477 MWh 4.406 MWh
Voltage/Current 249.1 V / 0.0 A 249.1 V / 10.2 A 249.1 V / 10.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/19/2021 22:21 (10.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.413 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.249 1.537 0.912 6.879 0.000 kW
1.488 kWh
0.000 kW
8.930 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.244 1.454 0.856 6.556
03 - 202224****** IQ7+M [0] ---- 0.000 0.247 1.517 0.910 6.832
04 - 202232****** IQ7+ [0] ---- 0.000 0.245 1.464 0.884 6.614
05 - 202244****** IQ7+M [0] ---- 0.000 0.244 1.503 0.891 6.678
06 - 202245****** IQ7+M [0] ---- 0.000 0.242 1.454 0.881 6.582
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.292 1.765 0.922 7.206 0.000 kW
1.765 kWh
0.000 kW
8.823 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.290 1.599 0.811 6.706
09 - 202217****** IQ7+ [0] ---- 0.000 0.294 1.836 0.980 7.441
10 - 202244****** IQ7+M [0] ---- 0.000 0.289 1.810 0.980 7.427
11 - 202224****** IQ7+M [0] ---- 0.000 0.291 1.813 0.963 7.368
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.158 0.885 0.736 4.974 0.000 kW
0.915 kWh
0.000 kW
3.660 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.157 0.921 0.731 5.014
14 - 202216****** IQ7+ [0] ---- 0.000 0.159 0.936 0.745 5.095
15 - 202245****** IQ7+M [0] ---- 0.000 0.156 0.918 0.735 5.016
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 500.7 Ah (25.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.5 % State Of Health 100.0 %
Run Time 17d 9h 14m to empty Report Date 2021-10-19 23:57
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.