Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.286 kW
07/09/2025 01:36 (1869 days) Production Consumption NET Usage
Now 0.000 kW 0.286 kW 0.286 kW
Today 0.000 kWh (0.000 kW) 1.526 kWh (0.925 kW) 1.526 kWh (0.925 kW)
  - This Week 74.549 kWh (24.294 kWh/day) 153.192 kWh (49.922 kWh/day) 78.643 kWh (25.628 kWh/day)
  - This Month 204.258 kWh (25.316 kWh/day) 321.918 kWh (39.899 kWh/day) 117.660 kWh (14.583 kWh/day)
  - This Year 3.234 MWh (17.105 kWh/day) 3.449 MWh (18.243 kWh/day) 0.215 MWh (1.138 kWh/day)
Yesterday 25.246 kWh (1.052 kW) 40.320 kWh (1.681 kW) 15.074 kWh (0.628 kW)
Last 7 Days 183.276 kWh (26.183 kWh/day) 289.029 kWh (41.290 kWh/day) 105.753 kWh (15.108 kWh/day)
Last 30 Days 633.297 kWh (21.111 kWh/day) 941.634 kWh (31.389 kWh/day) 308.337 kWh (10.278 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.479 MWh (17.750 kWh/day) 0.177 MWh (0.486 kWh/day)
Lifetime Since PTO 32.685 MWh (17.487 kW/day) 35.401 MWh (18.941 kW/day) 2.716 MWh (1.453 kW/day)
Lifetime Since Install 32.719 MWh 35.981 MWh 3.262 MWh
Voltage/Current 250.7 V / 0.0 A 250.7 V / 1.1 A 250.7 V / 1.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/07/2020 21:43 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.080 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.238 0.776 1.006 3.290 0.000 kW
0.755 kWh
0.000 kW
4.531 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.234 0.748 0.967 3.201
03 - 202224****** IQ7+M [0] V--- 0.000 0.237 0.727 0.943 3.170
04 - 202232****** IQ7+ [0] ---- 0.000 0.236 0.690 0.883 3.009
05 - 202244****** IQ7+M [0] ---- 0.000 0.238 0.796 1.066 3.427
06 - 202245****** IQ7+M [0] ---- 0.000 0.233 0.794 1.062 3.420
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.291 0.999 1.334 3.973 0.000 kW
1.010 kWh
0.000 kW
5.052 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.294 0.940 1.173 3.536
09 - 202217****** IQ7+ [0] ---- 0.000 0.295 1.050 1.448 4.246
10 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.050 1.429 4.222
11 - 202224****** IQ7+M [0] ---- 0.000 0.294 1.014 1.320 3.930
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.100 0.347 0.348 1.779 0.000 kW
0.374 kWh
0.000 kW
1.497 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.113 0.387 0.425 1.937
14 - 202216****** IQ7+ [0] ---- 0.000 0.113 0.386 0.419 1.935
15 - 202245****** IQ7+M [0] ---- 0.000 0.113 0.377 0.406 1.887
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.13 V Current/Power 165.92 A (8.816 kW)
Remain Capacity/Energy 411.9 Ah (21.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 69.7 % State Of Health 98.5 %
Run Time 1h 4m to full Report Date 2020-12-07 23:58
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.13 V Cell (MIN/MAX) 3.315 V / 3.325 V (0.010 V)
Current/Power -0.62 A (-32 W) Runtime 9d 6h 31m to empty
Remain Capacity/Energy 137.3 Ah (7.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 69.7 % State Of Health 98.5 %
Temperature 23.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-07 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.315 V 3.316 V 3.317 V 3.317 V 3.318 V 3.318 V 3.319 V 3.320 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.321 V 3.322 V 3.322 V 3.323 V 3.325 V 3.325 V 3.325 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -