Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.230 kW
07/09/2025 06:10 (1869 days) Production Consumption NET Usage
Now 0.045 kW 0.275 kW 0.230 kW
Today 0.006 kWh (0.001 kW) 4.398 kWh (0.708 kW) 4.392 kWh (0.707 kW)
  - This Week 74.555 kWh (22.879 kWh/day) 156.064 kWh (47.893 kWh/day) 81.509 kWh (25.014 kWh/day)
  - This Month 204.264 kWh (24.735 kWh/day) 324.790 kWh (39.329 kWh/day) 120.526 kWh (14.595 kWh/day)
  - This Year 3.234 MWh (17.088 kWh/day) 3.452 MWh (18.240 kWh/day) 0.218 MWh (1.152 kWh/day)
Yesterday 25.246 kWh (1.052 kW) 40.320 kWh (1.681 kW) 15.074 kWh (0.628 kW)
Last 7 Days 183.276 kWh (26.183 kWh/day) 289.029 kWh (41.290 kWh/day) 105.753 kWh (15.108 kWh/day)
Last 30 Days 633.297 kWh (21.111 kWh/day) 941.634 kWh (31.389 kWh/day) 308.337 kWh (10.278 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.479 MWh (17.750 kWh/day) 0.177 MWh (0.486 kWh/day)
Lifetime Since PTO 32.685 MWh (17.485 kW/day) 35.404 MWh (18.940 kW/day) 2.719 MWh (1.455 kW/day)
Lifetime Since Install 32.719 MWh 35.984 MWh 3.265 MWh
Voltage/Current 249.5 V / 0.2 A 249.5 V / 1.1 A 249.5 V / 0.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/05/2020 21:42 (8.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.176 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.185 0.279 0.207 3.504 0.000 kW
0.285 kWh
0.000 kW
1.712 kWh
02 - 202244****** IQ7+M [5] VC-- 0.000 0.186 0.282 0.203 3.394
03 - 202224****** IQ7+M [5] VC-- 0.000 0.184 0.293 0.208 3.355
04 - 202232****** IQ7+ [5] VC-- 0.000 0.184 0.290 0.205 3.189
05 - 202244****** IQ7+M [5] VCOP 0.000 0.186 0.290 0.202 3.657
06 - 202245****** IQ7+M [5] VCOP 0.000 0.187 0.279 0.204 3.651
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.260 0.326 0.190 4.142 0.000 kW
0.338 kWh
0.000 kW
1.692 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.259 0.334 0.188 3.579
09 - 202217****** IQ7+ [5] VCOP 0.000 0.261 0.343 0.191 4.440
10 - 202244****** IQ7+M [5] VCOP 0.000 0.260 0.344 0.194 4.427
11 - 202224****** IQ7+M [5] VC-- 0.000 0.257 0.345 0.191 4.079
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.079 0.190 0.202 1.977 0.000 kW
0.193 kWh
0.000 kW
0.772 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.083 0.194 0.204 2.134
14 - 202216****** IQ7+ [5] VCOP 0.000 0.081 0.196 0.207 2.131
15 - 202245****** IQ7+M [5] VCOP 0.000 0.080 0.192 0.203 2.078
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.17 V Current/Power 166.07 A (8.830 kW)
Remain Capacity/Energy 466.8 Ah (23.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 79.0 % State Of Health 98.5 %
Run Time 44m to full Report Date 2020-12-05 23:27
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.17 V Cell (MIN/MAX) 3.317 V / 3.328 V (0.011 V)
Current/Power -0.55 A (-29 W) Runtime 11d 18h 54m to empty
Remain Capacity/Energy 155.6 Ah (8.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 79.0 % State Of Health 98.5 %
Temperature 21.5 °C Cycle 27
MOSFET CFET = ON, DFET = ON Reported 2020-12-05 23:27
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.317 V 3.319 V 3.319 V 3.320 V 3.321 V 3.321 V 3.322 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.324 V 3.324 V 3.325 V 3.326 V 3.327 V 3.327 V 3.328 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -