Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.697 kW
07/09/2025 03:52 (1869 days) Production Consumption NET Usage
Now 0.000 kW 0.697 kW 0.697 kW
Today 0.000 kWh (0.000 kW) 3.693 kWh (0.944 kW) 3.693 kWh (0.944 kW)
  - This Week 74.549 kWh (23.569 kWh/day) 155.359 kWh (49.118 kWh/day) 80.810 kWh (25.549 kWh/day)
  - This Month 204.258 kWh (25.024 kWh/day) 324.085 kWh (39.704 kWh/day) 119.827 kWh (14.680 kWh/day)
  - This Year 3.234 MWh (17.096 kWh/day) 3.451 MWh (18.245 kWh/day) 0.217 MWh (1.149 kWh/day)
Yesterday 25.246 kWh (1.052 kW) 40.320 kWh (1.681 kW) 15.074 kWh (0.628 kW)
Last 7 Days 183.276 kWh (26.183 kWh/day) 289.029 kWh (41.290 kWh/day) 105.753 kWh (15.108 kWh/day)
Last 30 Days 633.297 kWh (21.111 kWh/day) 941.634 kWh (31.389 kWh/day) 308.337 kWh (10.278 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.479 MWh (17.750 kWh/day) 0.177 MWh (0.486 kWh/day)
Lifetime Since PTO 32.685 MWh (17.486 kW/day) 35.403 MWh (18.941 kW/day) 2.718 MWh (1.454 kW/day)
Lifetime Since Install 32.719 MWh 35.983 MWh 3.264 MWh
Voltage/Current 251.0 V / 0.0 A 250.9 V / 2.8 A 251.0 V / 2.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/03/2020 21:36 (9.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.878 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.228 0.918 0.381 3.296 0.000 kW
0.905 kWh
0.000 kW
5.431 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.224 0.887 0.368 3.188
03 - 202224****** IQ7+M [0] V--- 0.000 0.230 0.869 0.365 3.148
04 - 202232****** IQ7+ [0] ---- 0.000 0.226 0.814 0.355 2.994
05 - 202244****** IQ7+M [0] ---- 0.000 0.225 0.974 0.389 3.436
06 - 202245****** IQ7+M [0] ---- 0.000 0.225 0.969 0.396 3.430
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.292 1.171 0.424 3.805 0.000 kW
1.175 kWh
0.000 kW
5.876 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.030 0.341 3.234
09 - 202217****** IQ7+ [0] ---- 0.000 0.293 1.269 0.444 4.088
10 - 202244****** IQ7+M [0] ---- 0.000 0.292 1.261 0.441 4.080
11 - 202224****** IQ7+M [0] ---- 0.000 0.291 1.145 0.402 3.764
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.083 0.353 0.315 2.044 0.000 kW
0.393 kWh
0.000 kW
1.571 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.091 0.415 0.318 2.156
14 - 202216****** IQ7+ [0] ---- 0.000 0.090 0.407 0.321 2.160
15 - 202245****** IQ7+M [0] ---- 0.000 0.088 0.396 0.314 2.107
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.29 V Current/Power 166.36 A (8.865 kW)
Remain Capacity/Energy 583.2 Ah (29.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.7 % State Of Health 98.5 %
Run Time 2m to full Report Date 2020-12-03 23:31
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.29 V Cell (MIN/MAX) 3.324 V / 3.335 V (0.011 V)
Current/Power -0.56 A (-29 W) Runtime 14d 11h 46m to empty
Remain Capacity/Energy 194.4 Ah (10.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 98.7 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 27
MOSFET CFET = ON, DFET = ON Reported 2020-12-03 23:31
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.327 V 3.324 V 3.328 V 3.325 V 3.330 V 3.327 V 3.328 V 3.331 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.331 V 3.329 V 3.332 V 3.330 V 3.334 V 3.332 V 3.335 V 3.335 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -