Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.151 kW
07/08/2025 22:49 (1868 days) Production Consumption NET Usage
Now 0.000 kW 0.151 kW 0.151 kW
Today 25.246 kWh (1.105 kW) 38.661 kWh (1.692 kW) 13.415 kWh (0.587 kW)
  - This Week 74.549 kWh (25.249 kWh/day) 150.007 kWh (50.805 kWh/day) 75.458 kWh (25.557 kWh/day)
  - This Month 204.258 kWh (25.686 kWh/day) 318.733 kWh (40.081 kWh/day) 114.475 kWh (14.395 kWh/day)
  - This Year 3.234 MWh (17.115 kWh/day) 3.446 MWh (18.237 kWh/day) 0.212 MWh (1.122 kWh/day)
Yesterday 17.671 kWh (0.736 kW) 62.190 kWh (2.592 kW) 44.519 kWh (1.855 kW)
Last 7 Days 179.012 kWh (25.573 kWh/day) 280.072 kWh (40.010 kWh/day) 101.060 kWh (14.437 kWh/day)
Last 30 Days 628.494 kWh (20.950 kWh/day) 917.638 kWh (30.588 kWh/day) 289.144 kWh (9.638 kWh/day)
Last One Year 6.308 MWh (17.282 kWh/day) 6.469 MWh (17.724 kWh/day) 0.161 MWh (0.442 kWh/day)
Lifetime Since PTO 32.685 MWh (17.488 kW/day) 35.398 MWh (18.940 kW/day) 2.713 MWh (1.452 kW/day)
Lifetime Since Install 32.719 MWh 35.978 MWh 3.259 MWh
Voltage/Current 249.8 V / 0.0 A 249.7 V / 0.6 A 249.7 V / 0.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/22/2020 21:07 (8.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.277 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.042 0.158 0.841 5.800 0.000 kW
0.156 kWh
0.000 kW
0.935 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.041 0.154 0.814 5.685
03 - 202224****** IQ7+M [0] V--- 0.000 0.042 0.159 0.803 5.675
04 - 202232****** IQ7+ [0] ---- 0.000 0.041 0.156 0.767 5.479
05 - 202244****** IQ7+M [0] ---- 0.000 0.040 0.153 0.846 5.819
06 - 202245****** IQ7+M [0] ---- 0.000 0.041 0.155 0.840 5.759
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.037 0.140 0.912 6.573 0.000 kW
0.141 kWh
0.000 kW
0.703 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.037 0.139 0.801 5.954
09 - 202217****** IQ7+ [0] ---- 0.000 0.037 0.141 0.973 7.093
10 - 202244****** IQ7+M [0] ---- 0.000 0.037 0.143 0.969 7.036
11 - 202224****** IQ7+M [0] ---- 0.000 0.037 0.140 0.904 6.650
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.041 0.158 0.482 3.090 0.000 kW
0.160 kWh
0.000 kW
0.639 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.041 0.160 0.520 3.374
14 - 202216****** IQ7+ [0] ---- 0.000 0.042 0.162 0.521 3.363
15 - 202245****** IQ7+M [0] ---- 0.000 0.041 0.159 0.507 3.275
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 51.81 V Current/Power 161.80 A (8.383 kW)
Remain Capacity/Energy 166.8 Ah (8.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 28.2 % State Of Health 98.5 %
Run Time 2h 37m to full Report Date 2020-11-22 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 51.81 V Cell (MIN/MAX) 3.231 V / 3.244 V (0.013 V)
Current/Power -0.45 A (-23 W) Runtime 5d 3h 33m to empty
Remain Capacity/Energy 55.6 Ah (2.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 28.2 % State Of Health 98.5 %
Temperature 26.0 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-22 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.231 V 3.233 V 3.235 V 3.235 V 3.237 V 3.236 V 3.239 V 3.239 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.238 V 3.237 V 3.240 V 3.239 V 3.241 V 3.242 V 3.243 V 3.244 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -