Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.203 kW
05/23/2025 17:44 (1822 days) Production Consumption NET Usage
Now 2.756 kW 0.553 kW -2.203 kW
Today 13.967 kWh (0.787 kW) 7.672 kWh (0.432 kW) -6.295 kWh (-0.355 kW)
  - This Week 107.331 kWh (18.697 kWh/day) 128.537 kWh (22.392 kWh/day) 21.206 kWh (3.694 kWh/day)
  - This Month 423.966 kWh (18.644 kWh/day) 377.687 kWh (16.609 kWh/day) -46.279 kWh (-2.035 kWh/day)
  - This Year 2.247 MWh (15.744 kWh/day) 2.186 MWh (15.317 kWh/day) -0.061 MWh (-0.426 kWh/day)
Yesterday 6.005 kWh (0.250 kW) 12.709 kWh (0.529 kW) 6.704 kWh (0.279 kW)
Last 7 Days 134.531 kWh (19.219 kWh/day) 156.455 kWh (22.351 kWh/day) 21.924 kWh (3.132 kWh/day)
Last 30 Days 619.275 kWh (20.642 kWh/day) 521.298 kWh (17.376 kWh/day) -97.977 kWh (-3.266 kWh/day)
Last One Year 6.646 MWh (18.208 kWh/day) 6.300 MWh (17.261 kWh/day) -0.346 MWh (-0.947 kWh/day)
Lifetime Since PTO 31.698 MWh (17.390 kW/day) 34.138 MWh (18.729 kW/day) 2.440 MWh (1.339 kW/day)
Lifetime Since Install 31.732 MWh 34.718 MWh 2.986 MWh
Voltage/Current 252.9 V / 10.9 A 252.9 V / 2.2 A 252.9 V / -8.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/05/2020 22:42 (11.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.514 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.279 1.100 1.431 8.375 0.000 kW
1.082 kWh
0.000 kW
6.489 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.276 1.085 1.417 8.275
03 - 202224****** IQ7+M [5] VCOP 0.000 0.280 1.099 1.436 8.384
04 - 202232****** IQ7+ [5] VCOP 0.000 0.279 1.089 1.428 8.319
05 - 202244****** IQ7+M [5] VCOP 0.000 0.278 1.061 1.395 8.211
06 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.056 1.384 8.159
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.027 1.445 8.713 0.000 kW
1.027 kWh
0.000 kW
5.136 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.294 0.890 1.318 8.287
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.075 1.480 8.788
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.082 1.497 8.890
11 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.063 1.481 8.836
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.197 0.980 1.126 6.076 0.000 kW
0.972 kWh
0.000 kW
3.888 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.196 0.971 1.116 6.002
14 - 202216****** IQ7+ [5] VCOP 0.000 0.197 0.976 1.127 6.124
15 - 202245****** IQ7+M [5] VCOP 0.000 0.193 0.961 1.107 6.008
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Battery History
Voltage 56.02 V Current/Power 175.07 A (9.808 kW)
Remain Capacity/Energy 564.3 Ah (28.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 95.5 % State Of Health 98.5 %
Run Time 9m to full Report Date 2020-10-05 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.495 V / 3.506 V (0.011 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 188.1 Ah (9.6 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 95.5 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-10-05 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.499 V 3.495 V 3.501 V 3.502 V 3.502 V 3.498 V 3.505 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.502 V 3.500 V 3.503 V 3.499 V 3.505 V 3.501 V 3.505 V 3.506 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -