Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.033 kW
08/26/2025 11:27 (1917 days) Production Consumption NET Usage
Now 3.401 kW 0.368 kW -3.033 kW
Today 7.246 kWh (0.632 kW) 6.116 kWh (0.533 kW) -1.130 kWh (-0.098 kW)
  - This Week 54.074 kWh (21.822 kWh/day) 51.427 kWh (20.754 kWh/day) -2.647 kWh (-1.068 kWh/day)
  - This Month 607.177 kWh (23.831 kWh/day) 736.009 kWh (28.888 kWh/day) 128.832 kWh (5.057 kWh/day)
  - This Year 4.365 MWh (18.380 kWh/day) 5.074 MWh (21.364 kWh/day) 0.709 MWh (2.984 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.816 MWh (17.636 kW/day) 37.026 MWh (19.310 kW/day) 3.210 MWh (1.674 kW/day)
Lifetime Since Install 33.850 MWh 37.606 MWh 3.756 MWh
Voltage/Current 251.3 V / 13.5 A 251.3 V / 1.5 A 251.3 V / -12.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/31/2020 21:26 (7.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.444 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.085 0.173 0.534 4.105 0.000 kW
0.162 kWh
0.000 kW
0.975 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.077 0.154 0.480 3.738
03 - 202224****** IQ7+M [5] VCOP 0.000 0.081 0.166 0.491 3.748
04 - 202232****** IQ7+ [5] VCOP 0.000 0.082 0.170 0.492 3.692
05 - 202244****** IQ7+M [5] VCOP 0.000 0.075 0.149 0.503 4.091
06 - 202245****** IQ7+M [5] VCOP 0.000 0.079 0.162 0.531 4.239
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.081 0.159 0.621 5.326 0.000 kW
0.160 kWh
0.000 kW
0.800 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.082 0.157 0.565 4.764
09 - 202217****** IQ7+ [5] VCOP 0.000 0.083 0.161 0.633 5.627
10 - 202244****** IQ7+M [5] VCOP 0.000 0.084 0.163 0.638 5.589
11 - 202224****** IQ7+M [5] VCOP 0.000 0.083 0.160 0.615 5.255
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.071 0.166 0.375 1.861 0.000 kW
0.167 kWh
0.000 kW
0.670 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.072 0.167 0.389 2.121
14 - 202216****** IQ7+ [5] VCOP 0.000 0.073 0.170 0.394 2.113
15 - 202245****** IQ7+M [5] VCOP 0.000 0.071 0.167 0.387 2.055
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.24 V Current/Power 166.28 A (8.853 kW)
Remain Capacity/Energy 509.7 Ah (26.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 86.2 % State Of Health 98.5 %
Run Time 29m to full Report Date 2020-12-31 23:21
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.24 V Cell (MIN/MAX) 3.322 V / 3.332 V (0.010 V)
Current/Power -0.26 A (-13 W) Runtime 27d 0h 28m to empty
Remain Capacity/Energy 169.9 Ah (8.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 86.2 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2020-12-31 23:21
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.323 V 3.324 V 3.324 V 3.325 V 3.326 V 3.327 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.328 V 3.329 V 3.329 V 3.330 V 3.330 V 3.332 V 3.331 V 3.332 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -