Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.360 kW
08/26/2025 11:44 (1917 days) Production Consumption NET Usage
Now 3.627 kW 0.267 kW -3.360 kW
Today 8.196 kWh (0.698 kW) 6.203 kWh (0.528 kW) -1.993 kWh (-0.170 kW)
  - This Week 55.024 kWh (22.105 kWh/day) 51.514 kWh (20.695 kWh/day) -3.510 kWh (-1.410 kWh/day)
  - This Month 608.127 kWh (23.858 kWh/day) 736.096 kWh (28.879 kWh/day) 127.969 kWh (5.020 kWh/day)
  - This Year 4.366 MWh (18.383 kWh/day) 5.074 MWh (21.364 kWh/day) 0.708 MWh (2.981 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.817 MWh (17.636 kW/day) 37.026 MWh (19.309 kW/day) 3.209 MWh (1.674 kW/day)
Lifetime Since Install 33.851 MWh 37.606 MWh 3.755 MWh
Voltage/Current 250.8 V / 14.5 A 250.7 V / 1.1 A 250.8 V / -13.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/30/2020 21:47 (8.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.649 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.169 0.534 0.761 4.329 0.000 kW
0.505 kWh
0.000 kW
3.033 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.163 0.480 0.696 3.953
03 - 202224****** IQ7+M [5] VCOP 0.000 0.165 0.491 0.676 3.941
04 - 202232****** IQ7+ [5] VCOP 0.000 0.168 0.492 0.650 3.868
05 - 202244****** IQ7+M [5] VCOP 0.000 0.161 0.503 0.777 4.342
06 - 202245****** IQ7+M [5] VCOP 0.000 0.164 0.531 0.816 4.503
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.210 0.621 1.044 5.654 0.000 kW
0.614 kWh
0.000 kW
3.072 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.205 0.565 0.873 4.999
09 - 202217****** IQ7+ [5] VCOP 0.000 0.209 0.633 1.111 6.034
10 - 202244****** IQ7+M [5] VCOP 0.000 0.211 0.638 1.095 5.973
11 - 202224****** IQ7+M [5] VCOP 0.000 0.208 0.615 1.019 5.546
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.105 0.375 0.338 1.863 0.000 kW
0.386 kWh
0.000 kW
1.544 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.107 0.389 0.385 2.146
14 - 202216****** IQ7+ [5] VCOP 0.000 0.106 0.394 0.382 2.135
15 - 202245****** IQ7+M [5] VCOP 0.000 0.103 0.387 0.372 2.071
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.27 V Current/Power 166.36 A (8.861 kW)
Remain Capacity/Energy 515.1 Ah (26.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 87.2 % State Of Health 98.5 %
Run Time 27m to full Report Date 2020-12-30 23:57
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.27 V Cell (MIN/MAX) 3.323 V / 3.333 V (0.010 V)
Current/Power -0.25 A (-13 W) Runtime 28d 3h 59m to empty
Remain Capacity/Energy 171.7 Ah (8.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 87.2 % State Of Health 98.5 %
Temperature 18.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2020-12-30 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.325 V 3.325 V 3.326 V 3.327 V 3.327 V 3.328 V 3.328 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.329 V 3.330 V 3.330 V 3.331 V 3.332 V 3.333 V 3.333 V 3.333 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -