Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.641 kW
08/26/2025 12:32 (1917 days) Production Consumption NET Usage
Now 4.015 kW 0.374 kW -3.641 kW
Today 11.231 kWh (0.895 kW) 6.430 kWh (0.512 kW) -4.801 kWh (-0.383 kW)
  - This Week 58.059 kWh (23.013 kWh/day) 51.741 kWh (20.509 kWh/day) -6.318 kWh (-2.504 kWh/day)
  - This Month 611.162 kWh (23.946 kWh/day) 736.323 kWh (28.849 kWh/day) 125.161 kWh (4.904 kWh/day)
  - This Year 4.369 MWh (18.393 kWh/day) 5.074 MWh (21.362 kWh/day) 0.705 MWh (2.968 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.820 MWh (17.637 kW/day) 37.026 MWh (19.309 kW/day) 3.206 MWh (1.672 kW/day)
Lifetime Since Install 33.854 MWh 37.606 MWh 3.752 MWh
Voltage/Current 250.3 V / 16.0 A 250.2 V / 1.5 A 250.2 V / -14.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/28/2020 23:03 (9.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.449 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.196 0.674 0.922 3.000 0.000 kW
0.651 kWh
0.000 kW
3.908 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.192 0.635 0.851 2.798
03 - 202224****** IQ7+M [5] VCOP 0.000 0.193 0.655 0.834 2.892
04 - 202232****** IQ7+ [5] VCOP 0.000 0.194 0.642 0.801 2.931
05 - 202244****** IQ7+M [5] VCOP 0.000 0.192 0.644 0.928 3.745
06 - 202245****** IQ7+M [5] VCOP 0.000 0.195 0.659 0.974 3.968
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.253 0.899 1.220 4.931 0.000 kW
0.913 kWh
0.000 kW
4.567 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.251 0.900 1.058 3.984
09 - 202217****** IQ7+ [5] VCOP 0.000 0.255 0.924 1.313 5.532
10 - 202244****** IQ7+M [5] VCOP 0.000 0.255 0.926 1.302 5.493
11 - 202224****** IQ7+M [5] VCOP 0.000 0.254 0.918 1.191 4.605
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.071 0.212 0.337 1.875 0.000 kW
0.244 kWh
0.000 kW
0.974 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.086 0.258 0.409 2.140
14 - 202216****** IQ7+ [5] VCOP 0.000 0.086 0.255 0.404 2.135
15 - 202245****** IQ7+M [5] VCOP 0.000 0.083 0.249 0.394 2.071
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.24 V Current/Power 166.27 A (8.852 kW)
Remain Capacity/Energy 503.1 Ah (25.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 85.1 % State Of Health 98.5 %
Run Time 31m to full Report Date 2020-12-28 23:05
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.24 V Cell (MIN/MAX) 3.321 V / 3.332 V (0.011 V)
Current/Power -0.25 A (-13 W) Runtime 27d 22h 48m to empty
Remain Capacity/Energy 167.7 Ah (8.6 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 85.1 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2020-12-28 23:05
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.323 V 3.323 V 3.324 V 3.324 V 3.326 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.328 V 3.328 V 3.328 V 3.329 V 3.329 V 3.331 V 3.331 V 3.332 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -