Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.450 kW
08/26/2025 13:12 (1917 days) Production Consumption NET Usage
Now 0.681 kW 0.231 kW -0.450 kW
Today 13.782 kWh (1.042 kW) 6.653 kWh (0.503 kW) -7.129 kWh (-0.539 kW)
  - This Week 60.610 kWh (23.760 kWh/day) 51.964 kWh (20.371 kWh/day) -8.646 kWh (-3.389 kWh/day)
  - This Month 613.713 kWh (24.019 kWh/day) 736.546 kWh (28.826 kWh/day) 122.833 kWh (4.807 kWh/day)
  - This Year 4.371 MWh (18.402 kWh/day) 5.074 MWh (21.360 kWh/day) 0.703 MWh (2.958 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.822 MWh (17.638 kW/day) 37.026 MWh (19.309 kW/day) 3.204 MWh (1.671 kW/day)
Lifetime Since Install 33.856 MWh 37.606 MWh 3.750 MWh
Voltage/Current 247.2 V / 2.8 A 247.2 V / 0.9 A 247.2 V / -1.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/23/2020 21:43 (8.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.680 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.193 0.758 0.098 0.296 0.000 kW
0.726 kWh
0.000 kW
4.355 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.173 0.695 0.166 0.354
03 - 202224****** IQ7+M [5] VCOP 0.000 0.166 0.684 0.260 0.475
04 - 202232****** IQ7+ [5] VCOP 0.000 0.164 0.668 0.332 0.547
05 - 202244****** IQ7+M [5] VCOP 0.000 0.174 0.754 0.526 1.008
06 - 202245****** IQ7+M [5] VCOP 0.000 0.184 0.796 0.571 1.138
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.237 0.949 0.703 1.394 0.000 kW
0.943 kWh
0.000 kW
4.717 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.237 0.800 0.658 0.807
09 - 202217****** IQ7+ [5] VCOP 0.000 0.241 1.039 0.718 1.777
10 - 202244****** IQ7+M [5] VCOP 0.000 0.240 1.022 0.718 1.882
11 - 202224****** IQ7+M [5] VCOP 0.000 0.236 0.907 0.696 1.194
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.071 0.376 0.324 1.240 0.000 kW
0.402 kWh
0.000 kW
1.609 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.089 0.415 0.360 1.086
14 - 202216****** IQ7+ [5] VCOP 0.000 0.087 0.415 0.362 1.061
15 - 202245****** IQ7+M [5] VCOP 0.000 0.085 0.402 0.352 1.881
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 51.98 V Current/Power 162.28 A (8.435 kW)
Remain Capacity/Energy 193.5 Ah (9.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Run Time 2h 26m to full Report Date 2020-12-22 16:35
voltag, current for each battery pack voltage, current, and SOC

Voltage 51.98 V Cell (MIN/MAX) 3.241 V / 3.254 V (0.013 V)
Current/Power -0.50 A (-26 W) Runtime 5d 8h 30m to empty
Remain Capacity/Energy 64.5 Ah (3.3 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-22 16:35
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.241 V 3.242 V 3.244 V 3.244 V 3.249 V 3.245 V 3.249 V 3.249 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.248 V 3.248 V 3.251 V 3.249 V 3.252 V 3.253 V 3.254 V 3.254 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -