Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.152 kW
05/24/2025 03:01 (1823 days) Production Consumption NET Usage
Now 0.000 kW 0.152 kW 0.152 kW
Today 0.000 kWh (0.000 kW) 1.147 kWh (0.375 kW) 1.147 kWh (0.375 kW)
  - This Week 108.470 kWh (17.702 kWh/day) 136.127 kWh (22.215 kWh/day) 27.657 kWh (4.513 kWh/day)
  - This Month 425.105 kWh (18.381 kWh/day) 385.277 kWh (16.659 kWh/day) -39.828 kWh (-1.722 kWh/day)
  - This Year 2.248 MWh (15.709 kWh/day) 2.194 MWh (15.329 kWh/day) -0.054 MWh (-0.380 kWh/day)
Yesterday 15.106 kWh (0.630 kW) 14.115 kWh (0.589 kW) -0.991 kWh (-0.041 kW)
Last 7 Days 134.846 kWh (19.264 kWh/day) 157.675 kWh (22.525 kWh/day) 22.829 kWh (3.261 kWh/day)
Last 30 Days 604.047 kWh (20.136 kWh/day) 519.793 kWh (17.327 kWh/day) -84.254 kWh (-2.809 kWh/day)
Last One Year 6.642 MWh (18.196 kWh/day) 6.289 MWh (17.230 kWh/day) -0.353 MWh (-0.966 kWh/day)
Lifetime Since PTO 31.699 MWh (17.387 kW/day) 34.146 MWh (18.729 kW/day) 2.447 MWh (1.342 kW/day)
Lifetime Since Install 31.733 MWh 34.726 MWh 2.993 MWh
Voltage/Current 252.1 V / 0.0 A 252.1 V / 0.6 A 252.1 V / 0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/10/2020 23:21 (12.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.443 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.259 0.867 1.169 11.496 0.000 kW
0.859 kWh
0.000 kW
5.156 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.256 0.856 1.159 11.384
03 - 202224****** IQ7+M [0] ---- 0.000 0.256 0.869 1.179 11.594
04 - 202232****** IQ7+ [0] ---- 0.000 0.257 0.861 1.170 11.572
05 - 202244****** IQ7+M [0] ---- 0.000 0.256 0.848 1.131 11.038
06 - 202245****** IQ7+M [0] ---- 0.000 0.256 0.855 1.145 11.038
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.251 0.826 1.147 11.472 0.000 kW
0.830 kWh
0.000 kW
4.152 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.248 0.822 1.130 11.179
09 - 202217****** IQ7+ [0] ---- 0.000 0.253 0.833 1.142 11.385
10 - 202244****** IQ7+M [0] ---- 0.000 0.257 0.840 1.170 11.690
11 - 202224****** IQ7+M [0] ---- 0.000 0.253 0.832 1.159 11.658
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.231 0.781 1.034 10.020 0.000 kW
0.784 kWh
0.000 kW
3.135 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.228 0.782 1.030 9.822
14 - 202216****** IQ7+ [0] ---- 0.000 0.229 0.791 1.049 10.056
15 - 202245****** IQ7+M [0] ---- 0.000 0.226 0.781 1.035 9.902
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Battery History
Voltage 57.61 V Current/Power 180.01 A (10.371 kW)
Remain Capacity/Energy 582.6 Ah (29.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.6 % State Of Health 98.5 %
Run Time 2m to full Report Date 2020-09-10 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.