Exporting to grid by 5.249 kW
08/26/2025 14:26 (1917 days) Production Consumption NET Usage
Now 4.066 kW -1.183 kW -5.249 kW
Today 18.107 kWh (1.253 kW) 6.120 kWh (0.424 kW) -11.987 kWh (-0.830 kW)
  - This Week 64.935 kWh (24.957 kWh/day) 51.431 kWh (19.767 kWh/day) -13.504 kWh (-5.190 kWh/day)
  - This Month 618.038 kWh (24.140 kWh/day) 736.013 kWh (28.748 kWh/day) 117.975 kWh (4.608 kWh/day)
  - This Year 4.376 MWh (18.416 kWh/day) 5.074 MWh (21.353 kWh/day) 0.698 MWh (2.937 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.827 MWh (17.640 kW/day) 37.026 MWh (19.308 kW/day) 3.199 MWh (1.668 kW/day)
Lifetime Since Install 33.861 MWh 37.606 MWh 3.745 MWh
Voltage/Current 250.0 V / 16.3 A 250.1 V / -4.7 A 250.0 V / -21.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/12/2020 23:05 (8.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 1.445 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.037 0.107 0.738 4.248 0.000 kW
0.106 kWh
0.000 kW
0.633 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.037 0.105 0.709 4.121
03 - 202224****** IQ7+M [5] VCOP 0.000 0.038 0.108 0.692 4.079
04 - 202232****** IQ7+ [5] VCOP 0.000 0.037 0.105 0.657 3.877
05 - 202244****** IQ7+M [5] VCOP 0.000 0.037 0.103 0.756 4.415
06 - 202245****** IQ7+M [5] VCOP 0.000 0.037 0.105 0.777 4.422
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.034 0.094 0.914 5.337 0.000 kW
0.076 kWh
0.000 kW
0.380 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.000 2.931
09 - 202217****** IQ7+ [5] VCOP 0.000 0.034 0.095 0.981 5.728
10 - 202244****** IQ7+M [5] VCOP 0.000 0.034 0.096 0.971 5.672
11 - 202224****** IQ7+M [5] VCOP 0.000 0.033 0.094 0.888 5.334
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.038 0.107 0.348 2.079 0.000 kW
0.108 kWh
0.000 kW
0.432 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.038 0.108 0.390 2.302
14 - 202216****** IQ7+ [5] VCOP 0.000 0.039 0.110 0.389 2.301
15 - 202245****** IQ7+M [5] VCOP 0.000 0.038 0.107 0.375 2.234
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.21 V Current/Power 166.18 A (8.842 kW)
Remain Capacity/Energy 548.4 Ah (28.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 92.8 % State Of Health 98.5 %
Run Time 15m to full Report Date 2020-12-12 23:16
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.21 V Cell (MIN/MAX) 3.320 V / 3.329 V (0.009 V)
Current/Power -0.50 A (-26 W) Runtime 15d 5h 36m to empty
Remain Capacity/Energy 182.8 Ah (9.4 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 92.8 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-12 23:16
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.320 V 3.321 V 3.321 V 3.322 V 3.323 V 3.324 V 3.324 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.326 V 3.327 V 3.327 V 3.328 V 3.329 V 3.329 V 3.329 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -