Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.587 kW
08/26/2025 12:33 (1917 days) Production Consumption NET Usage
Now 3.993 kW 0.406 kW -3.587 kW
Today 11.302 kWh (0.899 kW) 6.438 kWh (0.512 kW) -4.864 kWh (-0.387 kW)
  - This Week 58.130 kWh (23.035 kWh/day) 51.749 kWh (20.506 kWh/day) -6.381 kWh (-2.529 kWh/day)
  - This Month 611.233 kWh (23.948 kWh/day) 736.331 kWh (28.849 kWh/day) 125.098 kWh (4.901 kWh/day)
  - This Year 4.369 MWh (18.394 kWh/day) 5.074 MWh (21.362 kWh/day) 0.705 MWh (2.968 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.820 MWh (17.637 kW/day) 37.026 MWh (19.309 kW/day) 3.206 MWh (1.672 kW/day)
Lifetime Since Install 33.854 MWh 37.606 MWh 3.752 MWh
Voltage/Current 250.3 V / 16.0 A 250.3 V / 1.6 A 250.3 V / -14.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/06/2020 23:24 (9.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.230 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.225 1.006 0.279 3.268 0.000 kW
0.988 kWh
0.000 kW
5.927 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.221 0.967 0.282 3.186
03 - 202224****** IQ7+M [5] VCOP 0.000 0.224 0.943 0.293 3.165
04 - 202232****** IQ7+ [5] VCOP 0.000 0.223 0.883 0.290 3.016
05 - 202244****** IQ7+M [5] VCOP 0.000 0.225 1.066 0.290 3.398
06 - 202245****** IQ7+M [5] VCOP 0.000 0.223 1.062 0.279 3.380
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.286 1.334 0.326 3.880 0.000 kW
1.341 kWh
0.000 kW
6.704 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.285 1.173 0.334 3.456
09 - 202217****** IQ7+ [5] VCOP 0.000 0.286 1.448 0.343 4.139
10 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.429 0.344 4.133
11 - 202224****** IQ7+M [5] VCOP 0.000 0.283 1.320 0.345 3.847
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.088 0.348 0.190 1.807 0.000 kW
0.400 kWh
0.000 kW
1.598 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.092 0.425 0.194 1.961
14 - 202216****** IQ7+ [5] VCOP 0.000 0.091 0.419 0.196 1.957
15 - 202245****** IQ7+M [5] VCOP 0.000 0.088 0.406 0.192 1.909
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.17 V Current/Power 166.04 A (8.828 kW)
Remain Capacity/Energy 453.0 Ah (23.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 76.6 % State Of Health 98.5 %
Run Time 49m to full Report Date 2020-12-06 23:50
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.17 V Cell (MIN/MAX) 3.317 V / 3.327 V (0.010 V)
Current/Power -0.56 A (-29 W) Runtime 11d 6h 36m to empty
Remain Capacity/Energy 151.0 Ah (7.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 76.6 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-06 23:50
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.317 V 3.318 V 3.319 V 3.320 V 3.321 V 3.321 V 3.321 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.323 V 3.324 V 3.325 V 3.326 V 3.327 V 3.327 V 3.327 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -