Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 4.931 kW
08/26/2025 13:44 (1917 days) Production Consumption NET Usage
Now 4.258 kW -0.673 kW -4.931 kW
Today 15.447 kWh (1.123 kW) 6.727 kWh (0.489 kW) -8.720 kWh (-0.634 kW)
  - This Week 62.275 kWh (24.206 kWh/day) 52.038 kWh (20.227 kWh/day) -10.237 kWh (-3.979 kWh/day)
  - This Month 615.378 kWh (24.064 kWh/day) 736.620 kWh (28.805 kWh/day) 121.242 kWh (4.741 kWh/day)
  - This Year 4.373 MWh (18.407 kWh/day) 5.074 MWh (21.358 kWh/day) 0.701 MWh (2.951 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.824 MWh (17.639 kW/day) 37.026 MWh (19.309 kW/day) 3.202 MWh (1.670 kW/day)
Lifetime Since Install 33.858 MWh 37.606 MWh 3.748 MWh
Voltage/Current 250.1 V / 17.0 A 250.0 V / -2.7 A 250.0 V / -19.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/03/2020 21:36 (9.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.878 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.228 0.918 0.381 3.296 0.000 kW
0.905 kWh
0.000 kW
5.431 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.224 0.887 0.368 3.188
03 - 202224****** IQ7+M [5] VCOP 0.000 0.230 0.869 0.365 3.148
04 - 202232****** IQ7+ [5] VCOP 0.000 0.226 0.814 0.355 2.994
05 - 202244****** IQ7+M [5] VCOP 0.000 0.225 0.974 0.389 3.436
06 - 202245****** IQ7+M [5] VCOP 0.000 0.225 0.969 0.396 3.430
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.292 1.171 0.424 3.805 0.000 kW
1.175 kWh
0.000 kW
5.876 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.030 0.341 3.234
09 - 202217****** IQ7+ [5] VCOP 0.000 0.293 1.269 0.444 4.088
10 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.261 0.441 4.080
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.145 0.402 3.764
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.083 0.353 0.315 2.044 0.000 kW
0.393 kWh
0.000 kW
1.571 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.091 0.415 0.318 2.156
14 - 202216****** IQ7+ [5] VCOP 0.000 0.090 0.407 0.321 2.160
15 - 202245****** IQ7+M [5] VCOP 0.000 0.088 0.396 0.314 2.107
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.29 V Current/Power 166.36 A (8.865 kW)
Remain Capacity/Energy 583.2 Ah (29.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.7 % State Of Health 98.5 %
Run Time 2m to full Report Date 2020-12-03 23:31
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.29 V Cell (MIN/MAX) 3.324 V / 3.335 V (0.011 V)
Current/Power -0.56 A (-29 W) Runtime 14d 11h 46m to empty
Remain Capacity/Energy 194.4 Ah (10.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 98.7 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 27
MOSFET CFET = ON, DFET = ON Reported 2020-12-03 23:31
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.327 V 3.324 V 3.328 V 3.325 V 3.330 V 3.327 V 3.328 V 3.331 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.331 V 3.329 V 3.332 V 3.330 V 3.334 V 3.332 V 3.335 V 3.335 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -