Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 5.017 kW
08/26/2025 14:37 (1917 days) Production Consumption NET Usage
Now 4.302 kW -0.715 kW -5.017 kW
Today 18.793 kWh (1.284 kW) 5.934 kWh (0.405 kW) -12.859 kWh (-0.879 kW)
  - This Week 65.621 kWh (25.145 kWh/day) 51.245 kWh (19.636 kWh/day) -14.376 kWh (-5.509 kWh/day)
  - This Month 618.724 kWh (24.160 kWh/day) 735.827 kWh (28.732 kWh/day) 117.103 kWh (4.573 kWh/day)
  - This Year 4.376 MWh (18.419 kWh/day) 5.073 MWh (21.352 kWh/day) 0.697 MWh (2.933 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.827 MWh (17.640 kW/day) 37.025 MWh (19.308 kW/day) 3.198 MWh (1.668 kW/day)
Lifetime Since Install 33.861 MWh 37.605 MWh 3.744 MWh
Voltage/Current 250.5 V / 17.2 A 250.4 V / -2.9 A 250.5 V / -20.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/20/2020 23:19 (9.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.365 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.207 1.040 0.935 5.231 0.000 kW
1.023 kWh
0.000 kW
6.136 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.205 1.011 0.918 5.212
03 - 202224****** IQ7+M [5] VCOP 0.000 0.209 1.003 0.920 5.235
04 - 202232****** IQ7+ [5] VCOP 0.000 0.208 0.972 0.884 5.066
05 - 202244****** IQ7+M [5] VCOP 0.000 0.209 1.060 0.928 5.159
06 - 202245****** IQ7+M [5] VCOP 0.000 0.206 1.051 0.926 4.982
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.265 1.251 1.076 5.960 0.000 kW
1.262 kWh
0.000 kW
6.311 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.265 1.112 1.012 5.455
09 - 202217****** IQ7+ [5] VCOP 0.000 0.264 1.347 1.153 6.500
10 - 202244****** IQ7+M [5] VCOP 0.000 0.264 1.341 1.148 6.438
11 - 202224****** IQ7+M [5] VCOP 0.000 0.264 1.261 1.100 6.104
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.102 0.434 0.504 2.887 0.000 kW
0.479 kWh
0.000 kW
1.917 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.102 0.502 0.540 3.138
14 - 202216****** IQ7+ [5] VCOP 0.000 0.102 0.498 0.538 3.064
15 - 202245****** IQ7+M [5] VCOP 0.000 0.100 0.484 0.525 3.035
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.37 V Current/Power 163.55 A (8.566 kW)
Remain Capacity/Energy 242.4 Ah (12.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 41.0 % State Of Health 98.5 %
Run Time 2h 7m to full Report Date 2020-11-20 23:26
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.37 V Cell (MIN/MAX) 3.268 V / 3.278 V (0.010 V)
Current/Power -0.47 A (-24 W) Runtime 7d 2h 27m to empty
Remain Capacity/Energy 80.8 Ah (4.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 41.0 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-20 23:26
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.268 V 3.268 V 3.270 V 3.270 V 3.271 V 3.271 V 3.272 V 3.273 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.274 V 3.273 V 3.275 V 3.275 V 3.276 V 3.276 V 3.277 V 3.278 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -