Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.003 kW
07/09/2025 10:42 (1869 days) Production Consumption NET Usage
Now 2.490 kW 0.487 kW -2.003 kW
Today 5.664 kWh (0.527 kW) 8.642 kWh (0.805 kW) 2.978 kWh (0.277 kW)
  - This Week 80.213 kWh (23.267 kWh/day) 160.308 kWh (46.501 kWh/day) 80.095 kWh (23.233 kWh/day)
  - This Month 209.922 kWh (24.852 kWh/day) 329.034 kWh (38.953 kWh/day) 119.112 kWh (14.101 kWh/day)
  - This Year 3.240 MWh (17.101 kWh/day) 3.456 MWh (18.244 kWh/day) 0.217 MWh (1.144 kWh/day)
Yesterday 25.246 kWh (1.052 kW) 40.320 kWh (1.681 kW) 15.074 kWh (0.628 kW)
Last 7 Days 183.276 kWh (26.183 kWh/day) 289.029 kWh (41.290 kWh/day) 105.753 kWh (15.108 kWh/day)
Last 30 Days 633.297 kWh (21.111 kWh/day) 941.634 kWh (31.389 kWh/day) 308.337 kWh (10.278 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.479 MWh (17.750 kWh/day) 0.177 MWh (0.486 kWh/day)
Lifetime Since PTO 32.691 MWh (17.487 kW/day) 35.408 MWh (18.941 kW/day) 2.718 MWh (1.454 kW/day)
Lifetime Since Install 32.724 MWh 35.988 MWh 3.264 MWh
Voltage/Current 248.6 V / 10.0 A 248.6 V / 2.0 A 248.6 V / -8.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/25/2020 22:56 (11.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.334 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.238 1.299 0.761 11.418 0.000 kW
1.277 kWh
0.000 kW
7.662 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.234 1.288 0.855 11.426
03 - 202224****** IQ7+M [5] VCOP 0.000 0.237 1.228 0.789 11.523
04 - 202232****** IQ7+ [5] VCOP 0.000 0.237 1.297 0.784 11.458
05 - 202244****** IQ7+M [5] VCOP 0.000 0.237 1.274 0.825 11.191
06 - 202245****** IQ7+M [5] VCOP 0.000 0.234 1.276 0.847 11.121
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.261 1.349 0.826 11.982 0.000 kW
1.334 kWh
0.000 kW
6.672 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.262 1.279 0.697 11.225
09 - 202217****** IQ7+ [5] VCOP 0.000 0.263 1.343 0.772 11.982
10 - 202244****** IQ7+M [5] VCOP 0.000 0.262 1.343 0.739 12.067
11 - 202224****** IQ7+M [5] VCOP 0.000 0.263 1.359 0.740 12.018
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.184 0.978 0.715 8.949 0.000 kW
1.000 kWh
0.000 kW
4.000 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.185 0.986 0.705 8.723
14 - 202216****** IQ7+ [5] VCOP 0.000 0.186 1.010 0.687 8.947
15 - 202245****** IQ7+M [5] VCOP 0.000 0.183 1.026 0.736 8.854
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 56.02 V Current/Power 175.08 A (9.809 kW)
Remain Capacity/Energy 571.5 Ah (29.3 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 96.7 % State Of Health 98.5 %
Run Time 6m to full Report Date 2020-09-25 23:47
voltag, current for each battery pack voltage, current, and SOC

Voltage 56.02 V Cell (MIN/MAX) 3.494 V / 3.507 V (0.013 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 190.5 Ah (9.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 96.7 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-25 23:47
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.500 V 3.494 V 3.500 V 3.501 V 3.502 V 3.504 V 3.503 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.499 V 3.503 V 3.501 V 3.504 V 3.503 V 3.499 V 3.507 V 3.503 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -