Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.186 kW
08/26/2025 15:52 (1917 days) Production Consumption NET Usage
Now 0.498 kW 0.684 kW 0.186 kW
Today 20.497 kWh (1.290 kW) 6.750 kWh (0.425 kW) -13.747 kWh (-0.865 kW)
  - This Week 67.325 kWh (25.294 kWh/day) 52.061 kWh (19.559 kWh/day) -15.264 kWh (-5.735 kWh/day)
  - This Month 620.428 kWh (24.177 kWh/day) 736.643 kWh (28.706 kWh/day) 116.215 kWh (4.529 kWh/day)
  - This Year 4.378 MWh (18.422 kWh/day) 5.074 MWh (21.351 kWh/day) 0.696 MWh (2.929 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.829 MWh (17.641 kW/day) 37.026 MWh (19.308 kW/day) 3.197 MWh (1.667 kW/day)
Lifetime Since Install 33.863 MWh 37.606 MWh 3.743 MWh
Voltage/Current 248.1 V / 2.0 A 248.1 V / 2.8 A 248.1 V / 0.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/08/2020 21:56 (9.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.543 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.210 1.092 1.102 6.838 0.000 kW
1.094 kWh
0.000 kW
6.563 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.207 1.081 1.083 6.690
03 - 202224****** IQ7+M [5] VCOP 0.000 0.211 1.100 1.102 6.764
04 - 202232****** IQ7+ [5] VCOP 0.000 0.210 1.086 1.091 6.712
05 - 202244****** IQ7+M [5] VCOP 0.000 0.210 1.103 1.108 6.836
06 - 202245****** IQ7+M [5] VCOP 0.000 0.207 1.100 1.105 6.861
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.257 1.268 1.288 8.131 0.000 kW
1.315 kWh
0.000 kW
6.575 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.256 1.130 1.135 7.437
09 - 202217****** IQ7+ [5] VCOP 0.000 0.255 1.440 1.460 8.758
10 - 202244****** IQ7+M [5] VCOP 0.000 0.256 1.418 1.433 8.720
11 - 202224****** IQ7+M [5] VCOP 0.000 0.254 1.321 1.349 8.388
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.118 0.562 0.573 3.775 0.000 kW
0.601 kWh
0.000 kW
2.405 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.118 0.621 0.628 4.081
14 - 202216****** IQ7+ [5] VCOP 0.000 0.118 0.619 0.627 4.091
15 - 202245****** IQ7+M [5] VCOP 0.000 0.115 0.603 0.611 4.009
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.03 V Current/Power 178.16 A (10.161 kW)
Remain Capacity/Energy 589.8 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Run Time - to full Report Date 2020-11-08 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.03 V Cell (MIN/MAX) 3.551 V / 3.570 V (0.019 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.6 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.561 V 3.558 V 3.551 V 3.565 V 3.564 V 3.563 V 3.567 V 3.567 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.561 V 3.563 V 3.566 V 3.565 V 3.569 V 3.570 V 3.566 V 3.568 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -