Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.862 kW
08/26/2025 14:57 (1917 days) Production Consumption NET Usage
Now 1.928 kW 0.066 kW -1.862 kW
Today 19.245 kWh (1.285 kW) 5.987 kWh (0.400 kW) -13.258 kWh (-0.885 kW)
  - This Week 66.073 kWh (25.183 kWh/day) 51.298 kWh (19.551 kWh/day) -14.775 kWh (-5.631 kWh/day)
  - This Month 619.176 kWh (24.164 kWh/day) 735.880 kWh (28.719 kWh/day) 116.704 kWh (4.555 kWh/day)
  - This Year 4.377 MWh (18.419 kWh/day) 5.073 MWh (21.351 kWh/day) 0.697 MWh (2.931 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.828 MWh (17.640 kW/day) 37.025 MWh (19.308 kW/day) 3.198 MWh (1.668 kW/day)
Lifetime Since Install 33.862 MWh 37.605 MWh 3.744 MWh
Voltage/Current 247.8 V / 7.8 A 247.9 V / 0.3 A 247.9 V / -7.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/05/2020 23:20 (9.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.572 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.222 1.156 1.171 5.371 0.000 kW
1.153 kWh
0.000 kW
6.919 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.222 1.143 1.161 5.186
03 - 202224****** IQ7+M [5] VCOP 0.000 0.225 1.156 1.169 5.278
04 - 202232****** IQ7+ [5] VCOP 0.000 0.224 1.145 1.162 5.229
05 - 202244****** IQ7+M [5] VCOP 0.000 0.224 1.168 1.182 5.312
06 - 202245****** IQ7+M [5] VCOP 0.000 0.221 1.151 1.177 5.405
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.273 1.389 1.411 6.165 0.000 kW
1.414 kWh
0.000 kW
7.070 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.283 1.247 5.695
09 - 202217****** IQ7+ [5] VCOP 0.000 0.274 1.488 1.541 6.547
10 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.488 1.539 6.546
11 - 202224****** IQ7+M [5] VCOP 0.000 0.272 1.422 1.473 6.302
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.128 0.605 0.627 3.240 0.000 kW
0.646 kWh
0.000 kW
2.582 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.127 0.664 0.680 3.431
14 - 202216****** IQ7+ [5] VCOP 0.000 0.127 0.664 0.681 3.477
15 - 202245****** IQ7+M [5] VCOP 0.000 0.125 0.649 0.668 3.406
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.21 V Current/Power 166.18 A (8.842 kW)
Remain Capacity/Energy 537.9 Ah (27.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 91.0 % State Of Health 98.5 %
Run Time 19m to full Report Date 2020-11-05 23:08
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.21 V Cell (MIN/MAX) 3.320 V / 3.329 V (0.009 V)
Current/Power -0.50 A (-26 W) Runtime 14d 22h 36m to empty
Remain Capacity/Energy 179.3 Ah (9.2 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 91.0 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-05 23:08
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.320 V 3.321 V 3.321 V 3.323 V 3.323 V 3.324 V 3.324 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.326 V 3.326 V 3.327 V 3.328 V 3.329 V 3.329 V 3.329 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -