Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.634 kW
07/09/2025 10:44 (1869 days) Production Consumption NET Usage
Now 2.142 kW 0.508 kW -1.634 kW
Today 5.737 kWh (0.533 kW) 8.655 kWh (0.804 kW) 2.918 kWh (0.271 kW)
  - This Week 80.286 kWh (23.281 kWh/day) 160.321 kWh (46.488 kWh/day) 80.035 kWh (23.208 kWh/day)
  - This Month 209.995 kWh (24.857 kWh/day) 329.047 kWh (38.949 kWh/day) 119.052 kWh (14.092 kWh/day)
  - This Year 3.240 MWh (17.101 kWh/day) 3.456 MWh (18.244 kWh/day) 0.217 MWh (1.143 kWh/day)
Yesterday 25.246 kWh (1.052 kW) 40.320 kWh (1.681 kW) 15.074 kWh (0.628 kW)
Last 7 Days 183.276 kWh (26.183 kWh/day) 289.029 kWh (41.290 kWh/day) 105.753 kWh (15.108 kWh/day)
Last 30 Days 633.297 kWh (21.111 kWh/day) 941.634 kWh (31.389 kWh/day) 308.337 kWh (10.278 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.479 MWh (17.750 kWh/day) 0.177 MWh (0.486 kWh/day)
Lifetime Since PTO 32.691 MWh (17.487 kW/day) 35.408 MWh (18.940 kW/day) 2.718 MWh (1.454 kW/day)
Lifetime Since Install 32.725 MWh 35.988 MWh 3.264 MWh
Voltage/Current 248.4 V / 8.6 A 248.3 V / 2.0 A 248.4 V / -6.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/18/2020 23:11 (12.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.638 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.279 1.510 1.019 9.434 0.000 kW
1.502 kWh
0.000 kW
9.011 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.494 1.006 9.345
03 - 202224****** IQ7+M [5] VCOP 0.000 0.281 1.517 1.020 9.514
04 - 202232****** IQ7+ [5] VCOP 0.000 0.280 1.507 1.009 9.432
05 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.492 0.986 9.170
06 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.491 0.999 9.207
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.580 0.955 9.540 0.000 kW
1.584 kWh
0.000 kW
7.920 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.556 0.930 9.269
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.586 0.966 9.566
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.603 0.973 9.738
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.595 0.962 9.648
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.227 1.182 0.949 7.959 0.000 kW
1.177 kWh
0.000 kW
4.707 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.231 1.162 0.950 7.861
14 - 202216****** IQ7+ [5] VCOP 0.000 0.231 1.191 0.960 8.027
15 - 202245****** IQ7+M [5] VCOP 0.000 0.225 1.172 0.947 7.902
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.62 V Current/Power 180.00 A (10.372 kW)
Remain Capacity/Energy 576.9 Ah (29.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 97.6 % State Of Health 98.5 %
Run Time 4m to full Report Date 2020-09-18 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.62 V Cell (MIN/MAX) 3.587 V / 3.608 V (0.021 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 192.3 Ah (9.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 97.6 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-18 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.597 V 3.599 V 3.599 V 3.599 V 3.601 V 3.595 V 3.605 V 3.604 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.600 V 3.603 V 3.602 V 3.587 V 3.605 V 3.607 V 3.606 V 3.608 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -