Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.352 kW
11/02/2025 00:42 (1985 days) Production Consumption NET Usage
Now 0.000 kW 0.352 kW 0.352 kW
Today 0.000 kWh (0.000 kW) 0.308 kWh (0.421 kW) 0.308 kWh (0.421 kW)
  - This Week 0.000 kWh 0.308 kWh 0.308 kWh
  - This Month 16.938 kWh (16.439 kWh/day) 16.974 kWh (16.474 kWh/day) 0.036 kWh (0.035 kWh/day)
  - This Year 5.595 MWh (18.342 kWh/day) 6.349 MWh (20.815 kWh/day) 0.754 MWh (2.473 kWh/day)
Yesterday 16.938 kWh (0.706 kW) 16.666 kWh (0.694 kW) -0.272 kWh (-0.011 kW)
Last 7 Days 84.554 kWh (12.080 kWh/day) 69.017 kWh (9.861 kWh/day) -15.537 kWh (-2.220 kWh/day)
Last 30 Days 448.063 kWh (14.935 kWh/day) 470.201 kWh (15.673 kWh/day) 22.138 kWh (0.738 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.413 MWh (20.310 kWh/day) 1.205 MWh (3.300 kWh/day)
Lifetime Since PTO 35.046 MWh (17.655 kW/day) 38.301 MWh (19.295 kW/day) 3.255 MWh (1.640 kW/day)
Lifetime Since Install 35.080 MWh 38.881 MWh 3.802 MWh
Voltage/Current 255.3 V / 0.0 A 255.3 V / 1.4 A 255.3 V / 1.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/27/2020 21:50 (9.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.939 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.222 0.922 0.914 2.078 0.000 kW
0.885 kWh
0.000 kW
5.310 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.213 0.851 0.809 1.947
03 - 202224****** IQ7+M [0] ---- 0.000 0.216 0.834 0.802 2.059
04 - 202232****** IQ7+ [0] ---- 0.000 0.217 0.801 0.813 2.130
05 - 202244****** IQ7+M [0] ---- 0.000 0.215 0.928 0.979 2.817
06 - 202245****** IQ7+M [0] ---- 0.000 0.214 0.974 0.977 2.994
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.275 1.220 1.261 3.711 0.000 kW
1.217 kWh
0.000 kW
6.085 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.275 1.058 1.091 2.926
09 - 202217****** IQ7+ [0] ---- 0.000 0.278 1.313 1.357 4.240
10 - 202244****** IQ7+M [0] ---- 0.000 0.276 1.302 1.339 4.252
11 - 202224****** IQ7+M [0] ---- 0.000 0.277 1.191 1.229 3.414
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.073 0.337 0.313 1.631 0.000 kW
0.386 kWh
0.000 kW
1.544 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.089 0.409 0.387 1.784
14 - 202216****** IQ7+ [0] ---- 0.000 0.089 0.404 0.384 1.782
15 - 202245****** IQ7+M [0] ---- 0.000 0.087 0.394 0.368 1.816
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.40 V Current/Power 166.68 A (8.900 kW)
Remain Capacity/Energy 522.0 Ah (26.7 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 88.3 % State Of Health 98.5 %
Run Time 24m to full Report Date 2020-12-27 23:16
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.40 V Cell (MIN/MAX) 3.329 V / 3.344 V (0.015 V)
Current/Power -0.27 A (-14 W) Runtime 26d 15h 42m to empty
Remain Capacity/Energy 174.0 Ah (8.9 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 88.3 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2020-12-27 23:16
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.335 V 3.329 V 3.336 V 3.331 V 3.338 V 3.334 V 3.333 V 3.339 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.339 V 3.335 V 3.340 V 3.336 V 3.341 V 3.338 V 3.343 V 3.344 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -