Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.652 kW
07/09/2025 20:29 (1869 days) Production Consumption NET Usage
Now 0.000 kW 2.652 kW 2.652 kW
Today 25.046 kWh (1.220 kW) 32.436 kWh (1.580 kW) 7.390 kWh (0.360 kW)
  - This Week 99.595 kWh (25.833 kWh/day) 184.102 kWh (47.752 kWh/day) 84.507 kWh (21.919 kWh/day)
  - This Month 229.304 kWh (25.895 kWh/day) 352.828 kWh (39.845 kWh/day) 123.524 kWh (13.950 kWh/day)
  - This Year 3.259 MWh (17.166 kWh/day) 3.480 MWh (18.330 kWh/day) 0.221 MWh (1.164 kWh/day)
Yesterday 25.246 kWh (1.052 kW) 40.320 kWh (1.681 kW) 15.074 kWh (0.628 kW)
Last 7 Days 183.276 kWh (26.183 kWh/day) 289.029 kWh (41.290 kWh/day) 105.753 kWh (15.108 kWh/day)
Last 30 Days 633.297 kWh (21.111 kWh/day) 941.634 kWh (31.389 kWh/day) 308.337 kWh (10.278 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.479 MWh (17.750 kWh/day) 0.177 MWh (0.486 kWh/day)
Lifetime Since PTO 32.710 MWh (17.493 kW/day) 35.432 MWh (18.949 kW/day) 2.722 MWh (1.456 kW/day)
Lifetime Since Install 32.744 MWh 36.012 MWh 3.268 MWh
Voltage/Current 248.8 V / 0.0 A 248.8 V / 10.7 A 248.8 V / 10.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/01/2020 23:31 (12.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.468 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.285 0.729 1.066 10.447 0.000 kW
0.725 kWh
0.000 kW
4.349 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.284 0.722 1.054 10.291
03 - 202224****** IQ7+M [0] ---- 0.000 0.283 0.735 1.074 10.489
04 - 202232****** IQ7+ [0] ---- 0.000 0.284 0.727 1.063 10.483
05 - 202244****** IQ7+M [0] ---- 0.000 0.285 0.714 1.003 9.986
06 - 202245****** IQ7+M [0] ---- 0.000 0.285 0.722 1.027 10.119
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.287 0.697 1.003 10.126 0.000 kW
0.702 kWh
0.000 kW
3.508 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.287 0.698 0.978 10.126
09 - 202217****** IQ7+ [0] ---- 0.000 0.284 0.703 1.008 10.110
10 - 202244****** IQ7+M [0] ---- 0.000 0.286 0.708 1.023 10.365
11 - 202224****** IQ7+M [0] ---- 0.000 0.286 0.702 1.013 10.352
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.218 0.649 0.982 9.249 0.000 kW
0.653 kWh
0.000 kW
2.611 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.219 0.645 0.981 9.044
14 - 202216****** IQ7+ [0] ---- 0.000 0.222 0.663 0.998 9.273
15 - 202245****** IQ7+M [0] ---- 0.000 0.218 0.653 0.986 9.121
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.62 V Current/Power 179.92 A (10.366 kW)
Remain Capacity/Energy 589.2 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.7 % State Of Health 98.5 %
Run Time - to full Report Date 2020-09-01 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.62 V Cell (MIN/MAX) 3.584 V / 3.607 V (0.023 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.4 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.7 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-01 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.599 V 3.596 V 3.599 V 3.601 V 3.603 V 3.601 V 3.603 V 3.592 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.584 V 3.602 V 3.605 V 3.607 V 3.603 V 3.607 V 3.603 V 3.606 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -