Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.703 kW
08/26/2025 14:47 (1917 days) Production Consumption NET Usage
Now 0.929 kW 0.226 kW -0.703 kW
Today 19.017 kWh (1.284 kW) 5.951 kWh (0.402 kW) -13.066 kWh (-0.882 kW)
  - This Week 65.845 kWh (25.162 kWh/day) 51.262 kWh (19.589 kWh/day) -14.583 kWh (-5.573 kWh/day)
  - This Month 618.948 kWh (24.162 kWh/day) 735.844 kWh (28.725 kWh/day) 116.896 kWh (4.563 kWh/day)
  - This Year 4.377 MWh (18.419 kWh/day) 5.073 MWh (21.351 kWh/day) 0.697 MWh (2.932 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.828 MWh (17.640 kW/day) 37.025 MWh (19.308 kW/day) 3.198 MWh (1.668 kW/day)
Lifetime Since Install 33.861 MWh 37.605 MWh 3.744 MWh
Voltage/Current 246.7 V / 3.8 A 246.7 V / 0.9 A 246.7 V / -2.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/16/2020 22:08 (10.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 1.404 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.025 0.099 1.525 6.760 0.000 kW
0.097 kWh
0.000 kW
0.583 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.025 0.096 1.495 6.644
03 - 202224****** IQ7+M [5] VCOP 0.000 0.026 0.099 1.506 6.720
04 - 202232****** IQ7+ [5] VCOP 0.000 0.025 0.097 1.495 6.643
05 - 202244****** IQ7+M [5] VCOP 0.000 0.025 0.095 1.511 6.623
06 - 202245****** IQ7+M [5] VCOP 0.000 0.025 0.097 1.512 6.621
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.025 0.087 1.710 7.121 0.000 kW
0.087 kWh
0.000 kW
0.436 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.025 0.087 1.586 6.712
09 - 202217****** IQ7+ [5] VCOP 0.000 0.025 0.088 1.760 7.313
10 - 202244****** IQ7+M [5] VCOP 0.000 0.025 0.088 1.788 7.415
11 - 202224****** IQ7+M [5] VCOP 0.000 0.025 0.087 1.759 7.301
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.022 0.095 0.921 4.736 0.000 kW
0.096 kWh
0.000 kW
0.386 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.022 0.097 0.943 4.745
14 - 202216****** IQ7+ [5] VCOP 0.000 0.022 0.098 0.956 4.850
15 - 202245****** IQ7+M [5] VCOP 0.000 0.022 0.096 0.940 4.768
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.15 V Current/Power 166.02 A (8.824 kW)
Remain Capacity/Energy 437.1 Ah (22.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 74.0 % State Of Health 98.5 %
Run Time 55m to full Report Date 2020-10-16 23:57
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.15 V Cell (MIN/MAX) 3.316 V / 3.327 V (0.011 V)
Current/Power -0.55 A (-29 W) Runtime 11d 0h 54m to empty
Remain Capacity/Energy 145.7 Ah (7.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 74.0 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-10-16 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.316 V 3.318 V 3.318 V 3.319 V 3.320 V 3.321 V 3.320 V 3.321 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.323 V 3.323 V 3.324 V 3.325 V 3.326 V 3.326 V 3.327 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -